Thermal/Mechanical Design Guide
89
Heatsink Load Metrology
D
Heatsink Load Metrology
To ensure compliance to max socket loading value listed in
Table 4-3
, and to meet the
performance targets for Thermal Interface Material in
Table 5.3
, the Heatsink Static
Compressive Load can be assessed using the items listed below:
• HP34970A DAQ
• Omegadyne load cell, 100 lbf max (LCKD-100)
• Test board (0.062") with ILM & back plate installed
• 8 in-lbf pneumatic driver
• Heatsink
• Intel Xeon processor 5500 series Load Cell Fixture (
Figure D-1
)