Design Guide
113
Intel
®
82870P2 (P64H2)
8.2.7.7
Pull-Ups/Pull-Downs in Three or More Slot Serial Mode
All PCI signals should follow the
PCI Local Bus Specification, Revision 2.2
pull-up requirements
whether they are muxed or not. Any unused input signals should be pulled to 3.3 V through an
8.2
k
Ω
± 5% resistor to keep them from floating.
Table 8-13. Shift Register Input Data
Bit
Byte 0
Byte 1
Byte 2
Byte 3
0
Slot 1 switch (0 = closed)
Slot 1 fault# (0 = fault)
Slot 1 present bit 2
Slot 1 present bit 1
1
Slot 2 switch
Slot 2 fault#
Slot 2 present bit 2
Slot 2 present bit 1
2
Slot 3 switch
Slot 3 fault#
Slot 3 present bit 2
Slot 3 present bit 1
3
Slot 4 switch
Slot 4 fault#
Slot 4 present bit 2
Slot 4 present bit 1
4
Slot 5 switch
Slot 5 fault#
Slot 5 present bit 2
Slot 5 present bit 1
5
Slot 6 switch
Slot 6 fault#
Slot 6 present bit 2
Slot 6 present bit 1
6
Stutter (not used)
Stutter (not used)
Stutter (not used)
Stutter (not used)
7
Stutter (not used)
Stutter (not used)
Stutter (not used)
Stutter (not used)
Bit
Byte 4
Byte 5
Byte 6
Byte 7
0
Slot 1 M66EN
Slot 1 PCIXCAP1
Slot 1 PCIXCAP2
User Defined
1
Slot 2 M66EN
Slot 2 PCIXCAP1
Slot 2 PCIXCAP2
User Defined
2
Slot 3 M66EN
Slot 3 PCIXCAP1
Slot 3 PCIXCAP2
User Defined
3
Slot 4 M66EN
Slot 4 PCIXCAP1
Slot 4 PCIXCAP2
User Defined
4
Slot 5 M66EN
Slot 5 PCIXCAP1
Slot 5 PCIXCAP2
User Defined
5
Slot 6 M66EN
Slot 6 PCIXCAP1
Slot 6 PCIXCAP2
User Defined
6
Stutter (not used)
Stutter (not used)
Stutter (not used)
Stutter (not used)
7
Stutter (not used)
Stutter (not used)
Stutter (not used)
Stutter (not used)
Figure 8-15. Four Slot Stutter Logic Implementation Example
Slot 1 Switch
Slot 2 Switch
Slot 3 Switch
Slot 4 Switch
Slot5 Switch
Slot 6 Switch
Slot 1 Fault
Slot 2 Fault
Slot 4 Fault
Slot 5 Fault
Slot 6 Fault
Parallel Load
Incorrect Implementation
Correct Implementation
Serialization
Logic
Serialized
Data
Serial Clock In
Slot 3 Fault
Connected
Connected
Connected
Connected
Grounded
Grounded
Connected
Connected
Connected
Connected
Grounded
Grounded
Serialization
Logic
Parallel Load
Serialized
Data
Serial Clock In
Slot 1 Switch
Slot 2 Switch
Slot 3 Switch
Slot 4 Switch
Connected
Connected
Connected
Connected
Slot 1 Fault
Slot 2 Fault
Slot 4 Fault
Slot 3 Fault
Connected
Connected
Connected
Connected
Notice that Slot 5
and Slot 6 positions
have been skipped.
Summary of Contents for Xeon
Page 24: ...Introduction 24 Design Guide This page is intentionally left blank ...
Page 30: ...Component Quadrant Layout 30 Design Guide This page is intentionally left blank ...
Page 52: ...Platform Clock Routing Guidelines 52 Design Guide This page is intentionally left blank ...
Page 66: ...System Bus Routing Guidelines 66 Design Guide This page is intentionally left blank ...
Page 118: ...Intel 82870P2 P64H2 118 Design Guide This page is intentionally left blank ...
Page 146: ...I O Controller Hub 146 Design Guide This page is intentionally left blank ...
Page 148: ...Debug Port 148 Design Guide This page is intentionally left blank ...
Page 210: ...Schematic Checklist 210 Design Guide This page is intentionally left blank ...
Page 220: ...Layout Checklist 220 Design Guide This page is intentionally left blank ...
Page 222: ...Schematics 222 Design Guide This page is intentionally left blank ...