Design Guide
17
Introduction
1.2
Conventions and Terminology
This section defines conventions and terminology used throughout the design guide.
Convention/Terminology
Description
Aggressor
A network that transmits a coupled signal to another network.
AGTL+
The Xeon™ processor family system bus uses a bus technology called AGTL+,
or Assisted Gunning Transceiver Logic. AGTL+ buffers are open-drain, and
require pull-up resistors to provide the high logic level and termination. AGTL+
output buffers differ from GTL+ buffers with the addition of an active pMOS pull-
up transistor to assist the pull-up resistors during the first clock of a low-to-high
voltage transition.
Asynchronous GTL+
Xeon processors do not utilize CMOS voltage levels on any signals that connect
to the processor. As a result, legacy input signals such as A20M#, IGNNE#,
INIT#, LINT0/INTR, LINT1/NMI, PWRGOOD, SMI#, SLP#, and STPCLK# utilize
GTL+ input buffers. Legacy output signals (FERR# and IERR#) and non-AGTL+
signals (THERMTRIP# and PROCHOT#) also utilize GTL+ output buffers. All of
these signals follow the same DC requirements as AGTL+ signals, however the
outputs are not actively driven high (during a logical 0 to 1 transition) by the
processor (the major difference between GTL+ and AGTL+). These signals do
not have setup or hold time specifications in relation to BCLK[1:0], and are
therefore referred to as “Asynchronous GTL+ Signals”. However, all of the
Asynchronous GTL+ signals are required to be asserted for at least two BCLKs
in order for the processor to recognize them.
Bus Agent
A component or group of components that, when combined, represent a single
load on the AGTL+ bus.
Core Power
Core power refers to a power rail that is on only during full-power operation.
These power rails are on when the active-low PSON signal is asserted to the
power supply. The core power rails that are distributed directly from the power
supply are: +12 V, +5 V, and +3.3 V.
Crosstalk
The reception on a victim network of a signal imposed by aggressor network(s)
through inductive and capacitive coupling between the networks.
•
Backward Crosstalk – Coupling that creates a signal in a victim network that
travels in the opposite direction as the aggressor’s signal.
•
Forward Crosstalk – Coupling that creates a signal in a victim network that
travels in the same direction as the aggressor’s signal.
•
Even Mode Crosstalk – Coupling from a signal or multiple aggressors when
all the aggressors switch in the same direction that the victim is switching.
•
Odd Mode Crosstalk – Coupling from a signal or multiple aggressors when
all the aggressors switch in the opposite direction that the victim is switching.
Derived power
A derived power rail is any power rail that is generated from another power rail
using an on-board voltage regulator. For example, +2.5 V is derived from a +5 V
power rail using a voltage regulator.
Dual Processor (DP)
Used to specify a system configuration using two processors.
Electromagnetic
Compatibility (EMC)
The successful operation of electronic equipment in its intended electromagnetic
environment.
Electromagnetic
Interference (EMI)
Electromagnetic radiation from an electrical source that interrupts the normal
function of an electronic device.
Summary of Contents for Xeon
Page 24: ...Introduction 24 Design Guide This page is intentionally left blank ...
Page 30: ...Component Quadrant Layout 30 Design Guide This page is intentionally left blank ...
Page 52: ...Platform Clock Routing Guidelines 52 Design Guide This page is intentionally left blank ...
Page 66: ...System Bus Routing Guidelines 66 Design Guide This page is intentionally left blank ...
Page 118: ...Intel 82870P2 P64H2 118 Design Guide This page is intentionally left blank ...
Page 146: ...I O Controller Hub 146 Design Guide This page is intentionally left blank ...
Page 148: ...Debug Port 148 Design Guide This page is intentionally left blank ...
Page 210: ...Schematic Checklist 210 Design Guide This page is intentionally left blank ...
Page 220: ...Layout Checklist 220 Design Guide This page is intentionally left blank ...
Page 222: ...Schematics 222 Design Guide This page is intentionally left blank ...