11
6. Low battery sensor
The IVP 4101 PET smart sensor controls the battery level. If it is critical (equal to or below 2.5V), it will send the information
to the control panel.
If the sensor is configured in unsupervised mode (OOK) and the low battery signal is enabled in the control unit, the
information is sent during the trip. Otherwise, if the sensor is configured in supervised mode (FSK), low battery sending is
done during supervision and triggering.
Note:
consult the control panel manual to verify compatibility with low battery signaling and supervision.
To make the desired adjustments, follow the steps below:
» Open the IVP 4001 PET smart.
» Set the jumpers to the desired settings.
» Take a trigger to effect changes to the sensor configuration.
Note:
do not register the sensor in the central during the stabilization time, wait for it to start working in continuous mode.
To register the sensor code in the alarm control panel, check the procedure in the manual of the used alarm control panel
and trigger a trigger by moving in front of the sensor to complete its registration.
Jumper SENS (JP1)
Position
Condition
1
Maximum sensitivity
2
Minimal sensitivity
Jumper SUPERV (JP3)
Position
Condition
Closed
No (Unsupervised)
Open
Yes (Supervised)
Jumper INT/CONT (JP2)
Position
Condition
1
Smart Continuum
2
Economic
JP3
SUPERV
JP1
JP2
NÃO/SIM
SENS
ECO/CONT