23
7 Logging and data connections
Variable Name
Update
Time [ms]
CAN message ID
(decimal)
Byte Bit 0 Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7
SPM1 Flags C
1000
extended
(d1056 + slave ID)
(h420 + slave ID)
0
X
X
X
X
X
X
X
X
1
X
X
X
X
X
X
X
X
2
X
X
X
X
X
X
X
X
3
X
X
X
X
X
X
X
X
SPM1 Flags D
4
X
X
X
X
X
X
X
X
5
X
X
X
X
X
X
X
X
6
X
X
X
X
X
X
X
X
7
X
X
X
X
X
X
X
X
SPM2 Flags A
1000
extended
(d1064 + slave ID)
(h428 + slave ID)
0
X
X
X
X
X
X
X
X
1
X
X
X
X
X
X
X
X
2
X
X
X
X
X
X
X
X
3
X
X
X
X
X
X
X
X
SPM2 Flags B
4
X
X
X
X
X
X
X
X
5
X
X
X
X
X
X
X
X
6
X
X
X
X
X
X
X
X
7
X
X
X
X
X
X
X
X
SPM2 Flags C
1000
extended
(d10 + slave ID)
(h400 + slave ID)
0
X
X
X
X
X
X
X
X
1
X
X
X
X
X
X
X
X
2
X
X
X
X
X
X
X
X
3
X
X
X
X
X
X
X
X
SPM2 Flags D
4
X
X
X
X
X
X
X
X
5
X
X
X
X
X
X
X
X
6
X
X
X
X
X
X
X
X
7
X
X
X
X
X
X
X
X
Of the values that are not digital.
Variable Name
Update
Time [ms]
CAN
message ID
(decimal)
Scale
(units per bit)
Offset
(units)
Bits
Maximum
Value
Transferable
Tank Level [bar.g]
100
extended
(d1024 +
slave ID)
(h400 +
slave ID)
0.5
0
10
511.5
Battery Voltage [V]
0.1
0
10
102.3
Output Power [W]
10
0
10
10230
SPM Input Power [W]
2
0
10
2046
Battery Power [W]
10
0
10
10230