copper ports support network speeds of 10/100/1000 Mbps.
These two ports are located next to their corresponding SFP-type fiber slots, and each of these
RJ-45 ports is interchangeable with its corresponding SFP slot. The Gigabit copper port will
have the same number as its corresponding SFP slot. Once an SFP fiber slot is connected, the
correspondingly numbered RJ-45 port won’t function.
1.3.3 sfP slots for sfP Modules
The two SFP slots are designed to house Gigabit SFP modules that support network speeds
of 1000 Mbps. These slots are interchangeable with the two 1000Base-T ports, and the slots
have the same port numbers as their corresponding 1000Base-T ports. once an SFP slot is
connected via an SFP module, the correspondingly numbered 1000Base-T port won’t function.
2 installation
The location of the switch can greatly affect its performance. Follow these recommendations:
• Install the switch in an appropriate place based on the Specifications (Section 12) for the
acceptable temperature and humidity ranges.
• Install the switch in a location that isn’t affected by strong electromagnetic field generators
(such as motors), vibration, dust and direct sunlight.
• leave at least 10 cm of space at the front and rear of the unit for ventilation.
• Affix the provided rubber pads to the bottom of the switch to protect the case.
2.1 Placement of the device
For horizontal (desktop, shelf, etc.) installation of the switch, follow these steps.
1. Place the switch on a clean, flat and safe surface that has convenient access to AC power.
2. Separate the four self-adhesive rubber pads and attach them to the switch’s underside.
3. Connect the switch to an AC power source. (The green PWR led on the front panel should
light up.)
4. Connect the cables from the network partner devices to the ports on the front panel. (The
green lNK led on the front panel associated with the port should light.)
For vertical (wall, post, etc.) installation of the switch, simply use the underside of the unit as a
template to measure and mark the position of the holes on to the surface where the unit is to
be installed. Then use the two screws provided to mount the switch firmly in place.
WARNING:
Because invisible laser radiation may be emitted from the aperture of a
port when no cable is connected, avoid exposure to laser radiation and do not stare
into open apertures.
For rackmounting of the switch, attach brackets to each side of the switch and place the
brackets in the rack’s slots. Insert and tighten two screws to securely attach the bracket to the
rack on each side.
2.2 connections & indicators
The switch can be used to connect up to 10 network devices by employing a combination of
twisted-pair and fiber cabling paths at Ethernet, Fast Ethernet or Gigabit Ethernet speeds.
2.2.1 Power
The switch uses a DC power supply of 9 – 48 V DC. The power and redundant power
7
INSTALLATION