13
difference is 100
℃
; Grade 6:3600, relatively temperature difference is 120
℃
) alarm pixel number :1.
3.
Specifications
Items
ThermalTronix
TT-1009L-BFTC TT-1018L-BFTC
TT-1037L-BFTC
TT-1050L-BFTC
Detector
characteristics
Detector type
Uncooled FPA microbolometer
Array size
384×288
Pixel
25um
Spectral range
8
~
14um
Frame rate
50HZ
Lens
Focal length
9mm
18mm
37mm
50mm
F number
F1.1
Focus
Athermalized, focus-free
Free focus
range
0.8m~∞
3m~
∞
12m~∞
23m~
∞
NETD
≤100mK
Gain/Brightness
adjustment
Manual brightness/gain; auto brightness/manual gain; auto brightness/gain
Functions
Polarity
inversion
White/black hot mode
Digital zoom
2X
Calibration
Automatic/manual
Grayscale alarm
Yes
Interface
External power
DC10V-15V
Power
consumption
≤2.2W
Video output
PAL
Remote control
interface
RS485
,
PELCO-D/P Protocol
Environment
Operation
temperature
-20
℃
~ +50
℃
Storage
temperature
-40
℃
~ +70
℃
Weight
≤3KG
Size
(
mm
)
362*140*145
Note: Specifications are subject to change without notice