Intenza Stairclimbers Manual_____Troubleshooting_____Error Message
Error Message
WHEN THE DISPLAY SHOWS ANY OF THE MESSAGES BELOW, FOLLOW THE LISTED CORRECTIONS TO CHECK THE PROBLEM.
YOU MAY ALSO REFER TO THE SERVICE MANUAL FOR MORE DETAILS.
How To Use The Safety Stop Pull Cord
WHEN OPERATING THE STAIRCLIMBER, PLEASE ATTACH THE SAFETY STOP CLIP TO YOUR T
—
SHIRT.
When the safety stop pull cord becomes detached from your T—shirt the machine will automatically slow down to a stop. A message will be
displayed on the console— “
CHECK SAFETY KEY
”. In order to restart the Stairclimber, simply re—attach the safety key to the slot.
SOLUTION
If error code is 1, 2, 4, 6, 7, 9, 20, 21, 50, 55, 102, 103, 104 Console will display “Need Maintenance”.
Solution: Execute “Self Diagnosis” function to get error code for troubleshooting
Cause: Bad connection between console and USB board or USB stick
· Re—plug in USB
· Check cable connection between USB board and console or change cables if needed
· Change USB board
· Change console main board
· Check safety key is properly inserted
· Check safety key connection (cable and connector)
· Reboot system and check if any error code remains
· Change console main board
Check buzzer sound from LCB—
· If the period of the sound is 3 seconds, check the cable connection from LCB to Console
· If the period of the sound is 1 second, change LCB.
MESSAGE
NEED MAINTENANCE
USB STICK FAIL
CHECK SAFETY KEY (ERR8)
CHECK MEMORY (ERR 60) ;
CHECK CONSOLE PCB (ERR 10) ;
CHECK USB COMM (ERR 81) ;
CHECK LCB or Cable
(No error code and the reason
of this message)
550 Ci
550 Ce2
450 Ci2
450 Ci2S
21