background image

POWER DISTRIBUTOR

2

PD-6359A

Installation

Unpacking

Unpacking 

Although your PD-6359A is neither complicated nor difficult to operate, we recommend you take a few minutes
to  read  this  brief  manual  and  familiarize  yourself  with  the  important  information  regarding  product  features,
setup and operation.

As with most electronic devices, we strongly recommend you retain the original packaging. In the unlikely event
the product must be returned for servicing, the original packaging (or reasonable equivalent) is required.

Installation

Environment

Never place this product in an environment which could alter its performance or reduce its service life. Such
environments usually include high levels of heat, dust, moisture, and vibration.

IMPORTANT SAFETY INSTRUCTIONS

1.  Read these instructions.
2.  Keep these instructions.
3.  Heed all warnings.
4.  Follow all instructions.
5.  Do not use this apparatus near water.
6.  Clean only with dry cloth.
7.  Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8.  Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including

amplifiers) that produce heat.

9.  Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades

with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide
blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult
an electrician for replacement of the obsolete outlet.

10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and

the point where they exit from the apparatus.

11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus.

When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.

13. Unplug this apparatus during lightning storms or when unused for long periods of time.
14.  Refer  all  servicing  to  qualified  service  personnel.  Servicing  is  required  when  the

apparatus  has  been  damaged  in  any  way,  such  as  power-supply  cord  or  plug  is
damaged,  liquid  has  been  spilled  or  objects  have  fallen  into  the  apparatus,  the
apparatus has been exposed to rain or moisture, does not operate normally, or has
been dropped.

S3125A

S3125A

Summary of Contents for 5A0C828364DB-1

Page 1: ...Operation Manual Power Distributor PD 6359A Rack mount products in the Western Hemisphere North America South America and the Caribbean do not have handles installed due to customer preference...

Page 2: ...ing instructions are for use by qualified service personnel only To reduce the risk of electric shock do not perform any servicing other than that contained in the operating instructions unless you ar...

Page 3: ...fety Instructions 2 Features 3 Caution when assembling the Racks 3 Package and accessory includes 3 Equipment Setting and Checking 4 Front Panel 6 Rear Panel 7 Applications 10 Block Diagram 11 Specifi...

Page 4: ...er apparatus including amplifiers that produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding...

Page 5: ...Block 5 08mm pitch 3P x 1EA 3 User manual x 1EA Features RACK SYSTEM POWER CONTROL It controls the power of the rack system AC OUTLET TERMINAL It being consisted of UNSWITCHED 1 group and SWITCHED 3...

Page 6: ...t number Ex when number 1 and 3 switch is ON 1 and 4 is added so equipment number will be 5 2 TERMINATION Switch LOAD OPEN Setting 1 For the system linked by using RS 485 communication interface it is...

Page 7: ...devices connected to this device 2 Remove the AC power cord then check the operation status with battery power in case of black out To prepare the black out the battery and battery charger PB 6207 is...

Page 8: ...D 6359A s is switched to DC power battery from AC power due to a power failure then LED is turned on 5 SWITCHED LED After AC power or DC power is applied to the equipment then LED is turned on upon po...

Page 9: ...SWITCHED 2 SWITCHED 1 Ex If BY PASS setting switch is all OFF position then AC power is output from SWITCHED 3 and then after 2 sec AC power is output from SWITCHED 2 At 2 sec later after AC power ou...

Page 10: ...for stable data receiving transmitting of link in out For the details of Equipment Setting please refer to page 4 Caution communication error may occur if it is not set correctly 7 DC POWER OUTPUT TER...

Page 11: ...It may cause electric shock Power overloading may cause the power to be turned off automatically to protect the circuit of the equipment Remove the cable connected to the DC power output terminal UNSW...

Page 12: ...W N L H C REMOTE IN UNSWITCHED DC OUT 24V 1 2 4 8 1 2 3 4 16 ON ADDRESS BY PASS EMERGENCY OFF LINK TERM LOAD OPEN IN OUT MAX5A MAX5A MAX5A TOTAL MAX 5A SWITCHED 1 MAX10A 220 240V 50 60Hz 2400W SWITCHE...

Page 13: ...CHED AC OUTLET GROUP1 AC OUTLET GROUP2 AC OUTLET GROUP3 DC TERMINAL RACK ONLY DC TERMINAL EMERGENCY DC TERMINAL UNSWITCHED DC TERMINAL AMP ONLY HARDWARE MCU CONTROL DC SOURCE AC SOURCE CONTROL Display...

Page 14: ...A Max RACK ONLY 4 channel 24V 5A Max Sequential Power Delay BY PASS 2 sec 0 5 step Communication RS 485 Operation Temperature 10 C 40 C Power Source AC 220 240V 50 60Hz Power Consumption 5 8kW Weight...

Page 15: ...POWER DISTRIBUTOR 13 PD 6359A DIMENSIONS 440 280 482 132...

Page 16: ...le by contacting your warranty provider Variations and Options Variations and Options Variations Products supplied through legitimate sources are compatible with local AC power requirements Options No...

Page 17: ...15 PD 6359A NOTE...

Page 18: ...16 PD 6359A NOTE...

Page 19: ...POWER DISTRIBUTOR 17 PD 6359A...

Page 20: ...company but rather a global company that is truly international in scope with factories and offices in Korea and China and sales and marketing operations located in Japan Europe and the U S A With mo...

Reviews: