background image

TELEPHONE PAGING

Welcome

Welcome

A personal welcome to you from the management and employees of Inter-M

All of the co-workers here at Inter-M are dedicated to providing excellent products with inherently good value,
and we are delighted you have purchased one of our products.

We sincerely trust this product will provide years of satisfactory service, but if anything is not to your complete
satisfaction, we will endeavor to make things right.

Welcome to Inter-M, and thank you for becoming part of our worldwide extended family!

RISK OF ELECTRIC SHOCK

DO NOT OPEN 

Caution

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK.

DO NOT REMOVE COVER (OR BACK).

NO USER-SERVICEABLE PARTS INSIDE.

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

WaRninG

To prevent fire or shock hazard, do not
expose the unit to rain or moisture.

*WARNING FOR YOUR PROTECTION PLEASE READ THE FOLLOWING-WATER AND MOISTURE: Unit should not be used near water(e.g.

near a bathtub, washbowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool, etc). Care should be taken so than objects do
not fall and liquids are not spilled into the enclosure through openings.

*Do not install this equipment in a confined space such as a book case or similar unit.
*This apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such vases, shall be placed on the apparatus.
*This apparatus shall be connected to a mains socket outlet with a protective earthing connection.
*It has heed to be easy to disconnect the device. To disconnect the device from power, separate AC input cable from inlet or unplug the AC Cord.

Caution

*These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock, do not perform any servicing

other than that contained in the operating instructions unless you are qualified to do so.

notE
*

This equipment has been tested and found to comply with the limits for a Class A digital device,  pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against  harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will
be required to correct the interference at his own expense. 

This  symbol  is  intended  to  alert  the  user  to  the
presence  of  uninsulated  “dangerous  voltage”  within
the  product’s  enclosure  that  may  be  of  sufficient
magnitude  to  constitute  a  risk  of  electric  shock  to
persons.

This  symbol  is  intended  to  alert  the  user  to  the
presence  of  important  operation  and  maintenance
(servicing)  instructions  in  the  literature  accompanying
the appliance.

Caution: To prevent electric shock do not use this (polarized) plug with

an extension cord, receptacle or other outlet unless the blades
can be fully inserted to prevent blade exposure.

Attentions: Pour  prévenir  les  chocs  électriques  ne  pas  utiliser  cette

fiche  polarisée  avec  un  prolongateur,  une  prise  de  courant
on  une  autre  sortie  de  courant,  sauf  si  les  lames  peuvent
étre  insérées  à  fond  sans  en  laisser  aucune  partie  à
découvert.

Summary of Contents for TP-6231

Page 1: ...Operation Manual Telephone Paging TP 6231 Rack mount products in the Western Hemisphere North America South America and the Caribbean do not have handles installed due to customer preference...

Page 2: ...C input cable from inlet or unplug the AC Cord Caution These servicing instructions are for use by qualified service personnel only To reduce the risk of electric shock do not perform any servicing ot...

Page 3: ...onment 2 Important Safety Instructions 2 Features 3 Equipment Set up and Check List 4 Front Panel 7 Rear Panel 8 Operation Flow Chart 12 Applications 13 Block Diagram 14 Specifications 15 Service Proc...

Page 4: ...ther apparatus including amplifiers that produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A groundi...

Page 5: ...PE 2 wire same method as general telephone 4 wire Exchange interface type 2W E M OFF HOOK SIGNAL DETECT CALL END AUTO RESPONSE SERVICE ARS ARS function is available with voice prompts and broadcasting...

Page 6: ...ector pin assignment Used if you want to install a 2W E M where private exchange is installed 4 Broadcast Management Dial CODE Telephone broadcasting Dial Codes Based on dial buttons Note When the pag...

Page 7: ...ECS 6216P set address number of TP 6231 to 1 If Connected to RM2 terminal of ECS 6216P set address number of TP 6231 to 9 CHANNEL 1 START CODE 2 SET 3 Command types 4 Operation commands 5 CHANNEL Num...

Page 8: ...uipment address number will be 5 7 Setup the SECURUTY NUMBER DELAY TIME switch of rear panel If setup is wrong BROADCASTING LED on the front panel will be ON 8 Adjust the line output level by using vo...

Page 9: ...ment When the state is normal the LED flashes and when Off indicates fault 3 BROADCASTING LED LED will be ON if broadcasting is connected or being broadcasted 4 AC OUTLET SWITCH Turns rear AC OUTLET o...

Page 10: ...ts the equipment address number Should be set only when it is connected to ECS 6216P or RME 6108 Refer to page 5 of Equipment Setting for more detailed information 4 DATA AUDIO Terminal RJ 45 Connects...

Page 11: ...low will HANG UP or put the phone On hook if thetelephone is left Off hook 1 2 3 4 5 6 7 8 TEL OFF Signal timing adjustment Determine the number Device operation of RING method installation 1 2 3 4 MO...

Page 12: ...on rear panel Reference SERIAL OUT terminal If used remove the top cover and set the slide switch on the PCB board S7 to the RS 232 position 10 LINE OUT GAIN VOLUME Adjusts volume output level 11 LIN...

Page 13: ...terminal RX TX Figure below shows pin configuration and proper wiring TP 6231 Female Controller Pin No 1 2 3 4 5 6 7 8 9 TP 6231 Definition NC RxD TxD NC GND NC NC NC NC 2 RxD 3 TxD 5 GND 2 RxD 3 TxD...

Page 14: ...ong zone No press again Broadcasting Mode CH9 Operator mode On CH11 Operator mode Off Busy Checking CH5 Broadcasting connected and make announce after the chime Press after finishing broadcasting CH7...

Page 15: ...TELEPHONE PAGING 13 TP 6231 Applications Applications SOURCE...

Page 16: ...E DTMF RECEIVER DETECTOR SECURITY NUMBER SETTING SWITCH SETTING SWITCH DELAY TIME SETTING SWITCH UNIT ADDRESS MAIN PROCESSOR 5V OPERATING 4 LINE TYPE BROADCASTING 5 9 4 8 3 7 2 6 1 P1 RDED 9P CONNECTI...

Page 17: ...l to Noise ratio S N Better than 65dB AC OUTLET Switched AC 230V 50Hz 3A Remote Power control Circuit number 1 Circuit Speaker control circuit number 16 Circuit Output control All Zone 2group Individu...

Page 18: ...TELEPHONE PAGING 16 TP 6231 440 482 280 88 DIMENSIONS...

Page 19: ...e by contacting your warranty provider Variations and Options Variations and Options Variations Products supplied through legitimate sources are compatible with local AC power requirements Options No...

Page 20: ...any but rather a global company that is truly international in scope with factories and offices in Korea and China and sales and marketing operations located in Japan Europe and the U S A With more th...

Reviews: