Channel
– The channel that is being observed for the trigger. A value from
1
to
16384
may be
entered into this field. The channel number corresponds to the
global
channel number within
CueServer, not a local channel number in a single universe.
◦
Type
– The type of the DMX Trigger. Set to
Enter/Exit Range
for this type of trigger.
◦
Range
– A range of
decimal
DMX values for this trigger. Each field may be from
0
to
255
.
◦
Rules
– One or more rules configured to trigger whenever the input DMX channel either enters
or exits that range. Each rule may contain any actions or conditions as permitted by rules.