4.2 Wiring: Step-by-step procedure
Strip approx. 8 cm of the data cable.
Wrap the drain wire (6) around the end of the insulation of the data cable.
Feed the connection cable through the strain relief.
Install the strain relief in such a way that the end of the insulation with the drain wire is electrically
connected to the back panel of the housing (10).
Clamp the blue wire under a nut of the strain relief (12).
Now, connect all of the cables coming from the I/O controller board to the terminal strip of the terminal.
Then, connect the blue wire from the back panel of the housing to the PE terminal.
Plug the terminal strip into the terminal.
Hook in the terminal at the top and press it down until it rests against the wall.
Screw down the terminal on the bottom left side (11) using the M2 x 6 mm countersunk screw included in
delivery.
Insert the mortise lock on the bottom right side and lock the terminal (13).
Use the enclosed plastic strips to seal the mortise lock.