Installation/Dismantling 

 

 

 

Step 4:

 Reset disassembly mode, i.e. hold the disassembly card or an authorized 

credential in front of the knob module. 

 

 

 

Disassembly of the Knob Module (with 
Disassembly Card) 

 

Step 1:

"Wake up" the knob module by turning it on (if necessary).  

 

Step 2:

 Hold the disassembly card in front of the knob module. 

 

The knob module switches to disassembly mode.  

 

 

Step 3:

 Turn the knob module until the emergency power contacts are in the 9 o'clock 

position.  

 

 

 

Step 4:

 Disassemble the knob by turning it back and forth slightly while simultaneously 

pulling it gently.  

 

 

 
 

Summary of Contents for IF15x

Page 1: ...Installation and User Manual Electronic Lock Cylinder IF15x ...

Page 2: ...nologies Zettachring 16 D 70567 Stuttgart Germany 49 0711 1322 0 Internet Email info interflex eu irco com Website http www interflex de Ingersoll Rand s Security Technologies Sector is a leading global provider of products and services that make environments safe secure and productive The sector s market leading products include electronic and biometric access control systems time recording and p...

Page 3: ...ing 7 Installation of the Cylinder Body 7 Installation of the Knob Module with Disassembly Card 7 Disassembly of the Knob Module with Disassembly Card 8 Operation 9 Short Time Release 9 Daily Release Toggle Function 9 Batteries 11 Battery Warning 11 Low Power Adapter 13 Battery Change 14 Visual Audible Signals 17 Index 21 ...

Page 4: ......

Page 5: ...data Write complex settings to the locking cylinders in a convenient way Short Description IF 151 IF 152 IF 153 Double knob locking cylinder with one electronic knob brass nickel plated Double knob locking cylinder with two electronic knobs brass nickel plated Half cylinder with one electronic knob brass nickel plated Standard length 30 30mm lengths from 26 26 mm are possible Standard length 30 35...

Page 6: ...2 Introduction Scope of Delivery Scope of Delivery IF151 Mechanical knob Cylinder body Knob module Two batteries Fixing screw ...

Page 7: ...Introduction 3 Scope of Delivery IF152 Knob module Cylinder body Knob module Four batteries Fixing screw ...

Page 8: ...IF153 Half cylinder body Knob module Two batteries Fixing screw Technical Data Dimensions in mm Cylinder Dimensions of the cylinder for Euro profile locks according to DIN 18254 Electronic knob 40 41 Mechanical knob only IF 151 29 5 20 ...

Page 9: ...tery is empty Possible at any time external power source required low power adapter Environmental conditions Operating temperature 0 C to 55 C Storage temperature 40 C to 85 C Protection Category IP54 IP standard DIN EN 60529 Installation location Indoor and outdoor areas depending on product design In the event of use in outdoor areas the general outdoor conditions must be checked See also Low Po...

Page 10: ......

Page 11: ... every step Installation of the Cylinder Body Important Before assembling the knob module always check the freedom of movement of all components Step 1 Remove the fixing screw and dismantle the existing cylinder body Step 2 Insert the cylinder body and secure it with the fixing screw Installation of the Knob Module with Disassembly Card Step 1 Wake up the knob module by turning it Step 2 Hold the ...

Page 12: ...Disassembly Card Step 1 Wake up the knob module by turning it on if necessary Step 2 Hold the disassembly card in front of the knob module The knob module switches to disassembly mode Step 3 Turn the knob module until the emergency power contacts are in the 9 o clock position Step 4 Disassemble the knob by turning it back and forth slightly while simultaneously pulling it gently ...

Page 13: ... step Short Time Release Wake up the knob module by turning it Hold the authorized credential in front of the knob module or A visual acoustic signal sequence indicates that the knob module is in release mode green After approx 5 seconds the knob module switches back to idle mode i e it can be turned empty again See also Visual Audible Signals 17 Daily Release Toggle Function Please note For this ...

Page 14: ...1 green 1 three seconds 1 green 1 Warning The locking cylinder is now permanently engaged and the door can be opened and closed without a credential To remove the toggle function repeat the procedure See also Visual Audible Signals 17 ...

Page 15: ...rnings of the early level 1 can only be seen by administrators for whom the service flag is set on their credential Hint If possible change the battery at warning level 1 You thus prevent time consuming uncertainty and user questions when battery warnings occur Warning level 2 Time interval 1 Time interval 2 Time interval 3 Credential at knob Red LED Command execution Warning level 3 Time interval...

Page 16: ...desired action It thus reacts after a time delay Time interval 1 Time interval 2 Time interval 3 Credential at knob Red LED Command execution Action Insert new batteries You thus prevent time consuming uncertainty and user questions when the following battery warnings visible to the user occur See also Visual Audible Signals 17 Warning level 2 The following features are characteristic of warning l...

Page 17: ...ed action Immediately insert new batteries or contact the person responsible See also Visual Audible Signals 17 Battery Change 14 Low Power Adapter Using the low power adapter the knob module can be supplied with voltage externally at any time so that all functions can be performed even if the batteries are empty Procedure Insert the low power adapter In doing so ensure the correct alignment of th...

Page 18: ...dule New batteries Battery exchange card Time card Procedure Step 1 Wake up the knob module by turning it on Step 2 Hold the battery replacement card in front of the knob module The knob module switches to battery replacement mode The cover locking pins of the knob module are unblocked Step 3 Push in the locking pins with the battery replacement tool simultaneously and remove the cover ...

Page 19: ...ush in the locking pins and reattach the knob module cover Ensure that the locking pins engage correctly with the cover Step 7 Exit battery replacement mode i e hold the battery replacement card or an authorized credential in front of the knob module Step 8 for current firmware version no longer necessary Reset the time using the time card See also Visual Audible Signals 17 ...

Page 20: ......

Page 21: ... the door initialization card sound during motor flag Red No credential recognized then idle mode Red Credential authorized Configurable using the door initialization card sound during motor flag Green Credential unauthorized Red Credential has expired or outside of time model Red Daily release toggle 1 Configurable using the door initialization card sound during motor flag Green Comment 1 Signal ...

Page 22: ... 3 long continuous tone Red delay longer than warning level 2 Programming mode Meaning Acoustic signal Visual signal Start of programming mode Data transmission Orange duration depends on amount of data End of programming mode Red After the end of a data transmission a message appears on the PC After a successful firmware update the lock cylinder is automatically restarted reset signaling see belo...

Page 23: ...ur Meaning Acoustic signal Fault while access external EEPROM such as ee read without Powerup Coupling error RTC fault clock quartz defective Invalid interrupt for waking up SPI bus error when accessing the Mifare reader SPI bus error when accessing the radio chip SPI bus error when accessing the Legic reader See also Short Time Release 9 Daily Release Toggle Function 9 Battery Change 14 Battery W...

Page 24: ......

Page 25: ...embly 5 6 disassembly card 5 6 E emergency opening 11 F flashing signal 15 I installation 5 L LED 5V 15 M modules 1 2 3 O operation 7 P performance overview 1 4 permanent opening 7 R release door release 7 15 S scope of supply 1 short description 1 short time release 7 signal 15 signal transmitter 15 standard opening 7 standard release 7 T technical data 4 toggle 7 W wake up 5 6 12 15 Index ...

Reviews: