86
Since most SCSI disk drives are low-level formatted at the factory, this step is usually not
necessary. You must format a disk only if one of the following applies:
u
The disk drive was not low-level formatted at the factory
u
There are an excessive number of media errors detected on the disk drive
You do not need to use the Format option to erase existing information on your SCSI disks,
such as a DOS partition. That information is erased when you initialize the logical drive(s).
Rebuild Menu
Choose Rebuild from the Management menu to rebuild one or more failed disk drives.
Check Consistency Menu
Choose this option from the Management menu to verify the redundancy data in logical
drives using RAID levels 1, 3, or 5.
When you choose Check Consistency, the parameters of the existing logical drives on the
current controller and a selection menu listing the logical drives by number appear.
Press the arrow keys to highlight the desired logical drives. Press the spacebar to select or
deselect a drive for consistency checking. Press
F2
to select or deselect all the logical drives.
Press
F10
to begin the consistency check. A progress indicator for each selected logical drive
displays.