118
Configure RAID 10 by spanning two to four pairs of contiguous RAID 1 logical drives. The
RAID 1 logical drives must have the same stripe size.
Configure RAID 30 by spanning two contiguous RAID 3 logical drives. The RAID 3 logical
drives must have the same stripe size.
Configure RAID 50 by spanning two contiguous RAID 5 logical drives. The RAID 5 logical
drives must have the same stripe size
Flush Cache
If the MegaRAID system must be powered down rapidly, you must flush the contents of the
cache memory to preserve data integrity.
View Log
Select this option to display the MegaRAID event log. The events are stored in the file,
RAID.log.
Diagnostics
Select this option to run either internal or external diagnostics on a physical drive that is in a
Ready or Failed state. The external diagnostics divide into two catagories: sequential and
random.
Enclosure Management
Select this option to manage the physical drives in the RAID drive cabinets. Each enclosure
displays the status of a SCSI channel. You can remove and insert hard drives. A red light
on a drive indicates a failed channel or drive. Green indicates optimal conditions.
Summary of Contents for InterRAID-12