160
Error: Temperature threshold exceeded
Reason
Solution
Cooling fan failed.
Identify the failed fan using the Information Control
Panel. Refer to Chapter 8 for details on replacing the
fan.
Cooling fan vent blocked,
inadequate ventilation.
Remove blockage to allow air flow, or move system to
location with better ventilation.
InterRAID-8 Only
The following table provides troubleshooting guidelines specifically for the InterRAID-8 disk
array.
Error: All drives are dead
Reason
Solution
Satellite mode set to active.
In the Information Control Panel menu, select the
Options Menu. At SCSI ID Menu, press the down
arrow to locate Reset Default IDs and press the Enter
button.
Error: Upper bus drives appear dead and the Information Control Panel
displays, “Starting Single...”
Reason
Solution
Dual-channel configuration
intended, but on powerup single-
channel configuration displays.
The dual-channel SCSI bus
terminator board not seated
properly.
Power down the InterRAID cabinet and the system.
Open the fan bracket by loosening the two captive
screws on back of the InterRAID cabinet. Use the
handle on the dual-channel board to apply force and
seat the board.