3
RAID Controller Board
The RAID controller board incorporates a 32-bit RISC processor to control all functions
including SCSI bus transfers, RAID processing, configuration, data striping, error recovery,
and drive building.
Smart Cabinet Monitoring
The cabinet uses an intelligent interface (microprocessor) to alert the user in the event of an
abnormal system condition. The microprocessor resides on the SCSI bus and communicates
the level of fault-tolerance to the user through software, LEDs, and audible alarms. The
cabinet monitors its disk drives, power supplies, cooling fans and temperature and
continually reports to the LEDs and the Information Control Panel.
NOTE
The InterRAID-6 cabinet does not have an Information Control Panel.
SAF-TE Cabinet Monitoring
SCSI Accessed Fault-Tolerant Enclosure (SAF-TE) is a new method to alert the user of
abnormal system conditions. SAF-TE, in addition to the Smart Cabinet monitoring
functions listed above, allows reporting to the system of the cooling fan revolutions per
minute, power supply voltages and temperature in degrees, number of insertions per slot, and
number of powerup hours.
Door Lock
The front door uses an integrated door lock to prevent unauthorized access to the internal
components. Two keys are provided with the cabinet. To unlock the door, insert the key and
turn it counterclockwise. To lock the door, turn the key clockwise.
NOTE
After inserting the key into the lock, the key can only be removed when the door is locked.
Describing Applicable Intergraph Systems
The dual-channel InterRAID-8 is available as a deskside (tower) unit, and the rack-mount
version is available as dual-channel and single-channel, depending on the system to which it
is attached.