11
2. Remove the RAID disk drives from the carton labeled, “This box contains disk drives
loaded with operating system software....” For TD-xx desktop and deskside systems, the
first three drives (ID 0, 1, 2) contain the operating system. For the DTP Server systems,
all six disk drives contain the operating system.
The following table shows the order in which to install the boot disk drives:
Disk Drive Label
InterRAID-6 Slots
ADP CHN ID 6
Slot 6 (Top)
ADP CHN ID 5
Slot 5
ADP CHN ID 4
Slot 4
ADP CHN ID 2
Slot 3
ADP CHN ID 1
Slot 2
ADP CHN ID 0
Slot 1 (Bottom)
3. Install the boot disk drives in the primary InterRAID-6 cabinet. To insert a drive,
extend the drive latching clips and slide the drive into the slot. Push between the
latching clips until the drive connects. Close the drive latching clips until they snap into
place, locking the drive into the slot. Refer to the following figure.
CAUTION
Carefully insert the disk drives to avoid damaging the Single Connector Attachment (SCA)
connector.
4. Install the remaining RAID disk drives without labels into the primary cabinet. You can
install them in any order as long as the slots are filled sequentially upward (for example,
do not install drives in slots 4 and 6, leaving slot 5 empty).
Power Switch
Slot 1
Drive
Latching
Clips
(Open)