28
2. Connect a RAID SCSI cable to the channel 1 port on the RAID controller board in the
base unit, and to the channel 1 port on the InterRAID-12 cabinet.
Connecting Remaining Cabinets and Cables
To connect the remaining cabinets and cables:
1. Choose the proper power cord for the cabinet. Refer to the Power Supply Cord Selection
instruction sheet included in the accessory pack.
2. Connect the power cord to the InterRAID-12 cabinet.
3. Connect the other end of the power cord to an Uninterruptible Power Supply (UPS), if
available, or to a grounded, three-prong AC power outlet.
CAUTION
If the system does not connect to a UPS, data loss can occur if there is a power failure.
4. If you have additional cabinets, connect the RAID SCSI cables and power cords in the
same manner as instructed above.
5. Use the following table as a guide to install any secondary RAID controller boards.
Number of
RAID
Controllers
Primary
Secondary
Secondary
Secondary
One
PCI Slot 3
-
-
-
Two
PCI Slot 3
PCI Slot 2
-
-
Three
PCI Slot 3
PCI Slot 2
PCI Slot 1
-
Four
PCI Slot 3
PCI Slot 2
PCI Slot 1
PCI Slot 6
−
If PCI Slot 6 is not available, use PCI Slot 5.
−
For Intergraph deskside systems with internal RAID, the internal RAID subsystem
already contains the boot drives. The primary RAID controller board connects to
the internal RAID subsystem.
−
For Intergraph deskside systems with an internal hard disk drive, the boot drive is
the internal hard disk drive and does not require connection to a primary RAID
controller board. Any external cabinets and associated RAID controller boards are
secondary.
Summary of Contents for InterRAID-12
Page 1: ...InterRAID Hardware User s Guide January 1997 DHA018210 ...
Page 4: ......
Page 121: ...106 ...
Page 157: ...142 ...
Page 163: ...148 ...
Page 171: ...156 ...