60
Simultaneous initialization of two or more drives can be done.
Using cursor keys, move the required System drive box and hit
<Enter> to select. After selecting the required System drive(s),
move to the ‘START’ box and hit <Enter> to proceed with the
Initialization.
!!Warning: Initialization of the System drives will destroy data
on drives.
2. Press
ENTER
to select the system drive. If multiple system drives exist, press
ENTER
on
each for simultaneous initialization. A check mark indicates the selected system drives.
3. After selecting all the system drives to be initialized, select the Start box and then press
ENTER
. The following message displays:
Do you want to proceed with initialization?
4. Select YES to initialize all of the selected system drives. A progress bar indicates each
system drive initialized.
5. When the initialization of all system drives completes, press any key to save the
configuration and return to the DACCF Main Menu.
6. Ensure the Array Encl MGMT I/F option is set to Enabled. Refer to “09. Advanced
Functions,” in this chapter for more information about the Array Encl MGMT I/F option
and other hardware parameters.
06. Consistency Check
Use the Consistency Check option in the DACCF Main Menu to verify data consistency on
redundant system drives. You should always execute a Consistency Check after a system
crash or power interruption.
To perform a consistency check:
1. From the DACCF Main Menu, select Consistency Check. A list of current system
drives displays.
2. Use the cursor keys to select a system drive, and press
ENTER
. If the system drive you
select is not a redundant drive, the following message displays:
Cannot Check consistency of a non-redundant System drive
If the selected drive is redundant, the consistency check starts. When the consistency
check completes, a message displays the results. If inconsistent blocks were found, the
following message displays.
Do you want to restore consistency?
3. Select YES to restore consistency to the system drive.