67
MYLEX Disk Array Controller-Configuration Utility Version X.XX X/XX/XX
2 Channel - 7 Target DAC960P #1 Firmware version x.xx
Choose this option to view or edit the controllers
Hardware features like battery backup.
Use Cursor keys for selection, hit <ENTER> to select, <ESC> to Exit
Edit/View Parameters
Hardware Parameters
Physical Parameters
SCSI Xfer Parameters
Startup Parameters
Hardware Parameters
When you select Hardware Parameters, a menu similar to the following displays. Use the
arrow keys to select a parameter, and press
ENTER
to toggle the settings.
Hardware Parameters
Battery Backup
Disabaled
Array Enclosure Management
Enabled
StorageWorks Fault MGMT. (TM)
Disabled
NOTE
The default hardware parameters are: Battery Backup = Disabled, Array Enclosure
Management. I/F (AEMI) = Enabled, StorageWorks Fault MGMTI/F = Disabled.
The InterRAID-6, InterRAID-8, and InterRAID-12 disk arrays do not support the Battery
Backup option. Intergraph recommends connection to a UPS to guard against data loss.
The Array Enclosure Management I/F option should be set to Enabled each time you create a
new configuration. This option allows the Windows NT Server operating system to
recognize a failed drive and to begin the automatic on-line rebuild of the drive. Intergraph
recommends the automatic rebuild capability for every InterRAID configuration.
The StorageWorks Fault Management option is not used by the InterRAID-6, InterRAID-8,
and InterRAID-12 disk arrays. The default is Disabled.
Summary of Contents for InterRAID-12
Page 1: ...InterRAID Hardware User s Guide January 1997 DHA018210 ...
Page 4: ......
Page 121: ...106 ...
Page 157: ...142 ...
Page 163: ...148 ...
Page 171: ...156 ...