2
Before You Begin
WARNING
Disconnect the system from AC power before servicing internal components! Failure
to remove AC power may result in equipment damage or personal injury.
NOTE
“Right side” and “left side” are as seen from the front of the unit.
CAUTION
Follow all warnings and cautions in servicing instructions. If you fail to follow documented,
approved procedures, personal injury and damage to equipment can result.
CAUTION
Use an antistatic wrist strap for all servicing procedures to avoid the possibility of
electrostatic discharge.
CAUTION
Do not use the bottom portion of the face panel or the lip at the top, rear of the unit as a hand
hold when moving the system. Equipment damage and personal injury can result.
CAUTION
Do not overtighten screws and other fasteners to avoid damaging threads.
Tools
You will need the following tools to service the system:
u
Antistatic wrist strap
u
Antistatic mat connected to an earth ground
u
Quarter-inch nutdriver
u
No. 1 and No. 2 Phillips screwdrivers
u
Small or medium flat-blade standard screwdriver
You do not need any tools to open the TDZ 2000 GX1 case.
Protecting Against Electrostatic Discharge
Electrostatic discharge (ESD) can damage sensitive components inside the unit. Take the
following precautions when working with internal components:
u
Unplug the unit from AC power before servicing any electronic component inside the
chassis. Remember that the TDZ 2000 GX1 is always on when connected to AC power.
u
Touch the bare metal of the chassis to ensure the chassis and your body are at the same
electric potential.