Ethernet Interface Installation Instructions  

Registering the System 

Before selecting Submit in Step 4 of the online registration 

process, the following steps must be completed. 

To register or re-register the Ethernet Interface 
module: 

1.  Open the panel cover. 

2.  Enter Utility Access Code 1 (Dealer Code) if you are not 

already in program mode. 

3.  Press Option #. 

4. Press 

Test

. The system will begin listing the remote 

options and their values. 

5.  Listen until you hear the phrase “Remote Option 1 is off.”  

Important

: Remote Option 1 must be off in order for the 

module to register successfully. 

6.  Press Cancel to stop the panel from announcing option 

values. 

7. Press 

Add. 

8.  Press Option #. 

9. Press 

Test

10.  Press Option # repeatedly until you will hear the panel 

announce “Remote Option 2”. 

11.  Press Done. The panel announces “Remote Option 2 OK.” 

Wait 30 seconds before proceeding to Verify Registration. 

Verify Registration 

To verify the system was registered properly at the 
panel: 

1.  Press Option #. 

2. Press 

Test

. The system will begin listing the remote 

options and their values. 

3.  Listen until you hear the phrase “Remote Option 1 is on.” 

4.  Press Cancel so stop the panel from announcing option 

values. 

If the panel says “Remote Option 1 is off”, the system was not 

registered properly. Verify all connections are correct, Simon 

Option 89 is On, the LED’s on the module and Ethernet 

connector are flashing (must open panel cover to verify), and 

the Account Number is not already in use; then try to register 

the system again. See the Troubleshooting section for more 

information. 

To verify the system was registered properly:  

Follow the procedures on the premisesconnect.com website. 

Programming Options Reference 

The following options are used to customize the Ethernet Interface module and are programmed at the panel 

Table 1: Programming options 

Option No. 

Option 

Default 

Range 

Desired Setting 

Simon Option 89 

Serial Port Protocol 

Off 

On/Off 

 

Simon Option 90 

Comm Channel 1 Reports 

Off 

0, 1, Off 

 

Simon Option 91 

Comm Channel 2 Reports 

Off 

0, 1, Off 

 

Simon Option 92 

Comm Channel 3 Reports 

Off 

0, Off 

 

Remote Option 1 

Module Registration Status 

Off 

On/Off 

 

Remote Option 2 

Register Module Command 

N/A 

N/A 

 

Remote Option 3 

Dealer ID 

000 

1-10-digit numeric 

 

Remote Option 4 

Line Number 

0001 

1-10 digit numeric 

 

Remote Option 5 

DHCP On/Off 

On 

On/Off 

 

Remote Option 6 

Reset Module Command 

N/A 

N/A 

 

Remote Option 7 

Static Module IP Address 

192.168.000.049 

12-digit, 4 octet 

 

Remote Option 8 

Static Router IP Address 

192.168.000.001 

12-digit, 4 octet 

 

Remote Option 9 

Static Subnet Mask 

255.255.255.000 

12-digit, 4 octet 

 

Remote Option 10  Current Module IP Address Dynamic 

12-digit 

numeric   

Summary of Contents for 60-938

Page 1: ...ivating the communication channel between the module and the Simon panel 3 Connection Connecting the Ethernet Interface Module Simon Panel combination to a network 4 Registration Registering the syste...

Page 2: ...AC power Connection Connecting the Ethernet Interface Module to a Network There are several possible network configurations the Simon Ethernet Interface module System may take The following are guidel...

Page 3: ...tch or Router Cable or DSL Modem Standard Ethernet Cable Internet Modem and Router may be one Device Modem Router and Switch may be one Device Registration Registering the Ethernet Interface Module Re...

Page 4: ...er the Dealer ID using the numbered keys 7 Press Done The panel will repeat the Dealer ID Line Number The Line Number Remote Option 4 is a numeric identifier that can be up to 10 digits long The Line...

Page 5: ...the system was not registered properly Verify all connections are correct Simon Option 89 is On the LED s on the module and Ethernet connector are flashing must open panel cover to verify and the Acco...

Page 6: ...iver 1 Format 0 0 1 Remote Option 32 Receiver 2 IP Address 000 000 000 000 12 digit 4 octet Remote Option 33 Receiver 2 Number 0001 4 digit 0000 9999 Remote Option 34 Receiver 2 Poll Period 0000 4 dig...

Page 7: ...tration Status Default Off Range On Off When the Ethernet Interface module is successfully registered this option is switched On automatically This option must be Off before attempting to register or...

Page 8: ...which the Ethernet Interface module is connected This option cannot be programmed and is for review only Remote Option 12 Current Subnet Mask Default Dynamic Range 12 digit numeric This option stores...

Page 9: ...sconnect com To enter letters press 9 then the Minutes button The panel announces the letter A Continue pressing the Minutes button to progress through the alphabet Remote Option 24 Ping Page Extensio...

Page 10: ...ondary network receiver should use for this account Remote Option 34 Receiver 2 Poll Period Note In UL listed systems this option must be turned on and SIA format must be used Default 0000 Range 4 dig...

Page 11: ...rver Basically a proxy server holds the most commonly accessed and recently used content from the World Wide Web in order to provide quicker downloads for users and to increase server security It is c...

Page 12: ...nerates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarant...

Reviews: