background image

 

P/N 1040736 

• REV E • OCT12 

 

Smart Card Reader AL1191, AL-1193 
Installation Instructions 

Introduction 

This is the Smart Card Reader Installation Instructions for 

models AL-1191 and AL-1193. The smart card reader is a 

multifunction, all-purpose proximity card reader suitable for all 

locations (including outdoors) that require a short-range 

reader. You can connect the reader directly to the Alliance 

system RS485 databus. 

You can configure the reader through the control panel menu 

when it is connected to the system  databus, through the DGP 

menu when it is connected to the local databus, or you can use 

a configuration card. Refer to the Smart Card Reader 

Programming Manual for more information. 

The AL-1191 model is shipped with a white removable cover 

(there are five other colors available). 

Reader components 

Figure 1 below shows the reader components. 

Figure 1: Reader components 

 

Blue LED. 

Door open, disarmed. 

Red LED. 

Door open, armed 

Comms. 

LED control, buzzer control, power. 

Installation 

You should program the reader and change the default 

address (16) before you install the reader. Refer to the Smart 

Card Reader Programming Manual for programming details. 

You can mount the reader on any flat surface with two #6 (3 to 

3.5 mm diameter) panhead screws (Figure 1). We do not 

recommend using countersunk screws. 

You will experience a slightly reduced range if you mount the 

reader on a metal surface. If you mount the AL-1191 reader 

outdoors, ensure that the blue LED is at the top. 

To mount the reader, do the following: 

1.  Gently pry the AL-1191 cover sides away from the main 

reader body to remove cover and expose the mounting 

screws. Do not use excessive force or the reader can be 

irreparably damaged. 

2.  Mount the reader using the mounting screws. 

3.  Gently press the cover over the main body of the AL-1191 

reader until it locks into place. 

Wiring 

Table 1 below describes the reader wiring components. 

Table 1: Wiring com ponents 

Wire color 

Nam e 

Description 

Red 

 

Positiv e 9 to 14 VDC supply .

 

Black 

O V 

DC supply  ground.

 

Green 

D-/D0/Data

 

RS485 Data -, Wiegand Data 0 Absolute 

maximum, 12 V at 10 mA

 

White 

D+/D1/Clock

 

RS485 Data +, Wiegand  Data 1 Absolute 

maximum, 12 V at 10 mA

 

AL-1191 

Cover 

Blue  LED 

Red  LED 

Comms 

AL-1193 

Blue  LED 

Red  LED 

Comms 