background image

 

P/N 466-

2987 (ML) • REV A • ISS 26FEB19

 

 

3 / 6 

Set the satellite address using DIP switches (see 

Address DIP 

switch

” 

on page 2). Set the bus termination switch (TERM 

jumper), if required. 

Place the satellite cover onto the base and snap in place. 
Tighten the locking screw at the base until the satellite cover is 
firm. Do not overtighten. 

Connections 

Figure 2: 2-way audio system connection diagram 

(1)  Audio bus 
(2)  MI bus 
(3)  External power supply (optional) 
(4)  Advisor Advanced system databus 
(5)  ATS1522N bus 

System databus 

The system databus is used to connect remote devices to the 
Advisor Advanced control panel. Remote devices can be up to 
1.5 km from a control panel. 

Remote devices must be connected via a 2 pair twisted 
shielded data cable from the system databus connection. 
(WCAT 52 is recommended). 

The shield of the data cable should be connected to earth at 
the ATS control panel, and to each earth terminal (CON8, 
Figure 1, item 17) at ATS1521N in series. 

Observe the correct polarity while connecting the system 
databus. C

onnect: D+, D−, 0

 V, 12 V signals on the same 

connectors of ATS1521N and Advisor Advanced panel. 

Caution: 

Special care should be taken while connecting ATS 

LAN system databus signals (0 V, 12 V). Reversing the polarity 
can cause a damage of the ATS1521N module. 

Audio bus 

Use a shielded twisted pair cable for the audio bus connection 
(for example, WCAT52). 

Observe the correct polarity while connecting the audio bus. 
Connect A+ on ATS1521N to A+ on ATS1520/ATS1521N, and 
so 

A− to A−.

 

The shield of the audio cable should be connected to earth at 
the ATS control panel, and to each earth terminal (CON8, 
Figure 1, item 17) at ATS1521N in series. 

ATS1522N bus 

Use this bus to connect up to three ATS1522N audio satellites 
in parallel to ATS1521N. 

Use a shielded twisted pair cable for the ATS1522N bus 
connection (for example, WCAT52). 

The shield of the cable should be connected to earth at the 
ATS control panel, and to each earth terminal (CON8, 
Figure 1, item 17) at ATS1521N and ATS1522N in series.  

Observe the correct polarity while connecting the ATS1522N 
bus. See Table 1 below. 

Table 1: ATS1522N bus connections 

ATS1521N 
terminals 

ATS1522N 
terminals 

Description 

T−

 

T−

 

External tamper 

ATS1521N 
terminals 

ATS1522N 
terminals 

Description 

T+ 

T+ 

External tamper 

MIC−

 

MIC−

 

External microphone 

MIC+ 

MIC+ 

External microphone 

LS−

 

LS−

 

External loudspeaker 

LS+ 

LS+ 

External loudspeaker 

 

Configuring 2-way audio 

See 

Advisor Advanced Installation and Programming Manual 

for details on 2-way audio configuration. 

Specifications 

Power supply 

9 to 14 V

12 V

 nom. 

Current consumption: 
 

Standby 

 

Maximum 

 
10 mA 
35 mA 

Minimum sound level @ 10 m 

55 dB 

Microphone sensitivity range 

10 m 

Dimensions 

157 x 91 x 34 mm 

Weight 

201 g 

Operating temperature 

10 to +55°C 

Maximum relative humidity 

95% noncondensing 

Regulatory information 

Manufacturer 

PLACED ON THE MARKET BY: 
UTC Fire & Security Americas Corporation, Inc. 
3211 Progress Drive, Lincolnton, NC, 28092, USA 
AUTHORIZED EU REPRESENTATIVE: 
UTC Fire & Security B.V. 
Kelvinstraat 7, 6003 DH Weert, Netherlands 

Product warnings 
and disclaimers 

 

THESE PRODUCTS ARE INTENDED FOR 
SALE TO AND INSTALLATION BY QUALIFIED 
PROFESSIONALS. UTC FIRE & SECURITY 
CANNOT PROVIDE ANY ASSURANCE THAT 
ANY PERSON OR ENTITY BUYING ITS 

PRODUCTS, INCLUDING ANY “AUTHORIZED 
DEALER” OR “AUTHORIZED RESELLER”, IS 

PROPERLY TRAINED OR EXPERIENCED TO 
CORRECTLY INSTALL FIRE AND SECURITY 
RELATED PRODUCTS. 
For more information on warranty disclaimers and 
product safety information, please check 

https://firesecurityproducts.com/policy/product-
warning/

 or scan the QR code. 

Certification 

 

 

UTC Fire & Security hereby declares that this 
device is in compliance with the applicable 
requirements and provisions of one or more of the 
Directives 2014/30/EU and 2014/35/EU. For more 
information see www.utcfireandsecurity.com or 
www.interlogix.com. 

Reviews: