background image

ATS1745 Advisor Master IP Bus adaptor installation & Setup Guide

3

Preliminary, not for sales

LED indications

The RJ-45 Ethernet port LEDs (Figure 5 below) indicate the following:

Orange LED flickers during data transmission or reception.

Green LED is on when the link is good.

Figure 5: Side view of Ethernet port

The mode, fault, encryption LEDs (Figure 4, item 8, on page 2) are described in the
following tables.

Table 1: Mode, fault, encryption LED indications for an SLM

LED

Activity

Indication

Mode LED (top)

Single flash repeating
(once per second)

SLM mode (SW1 ON)

Fault LED (middle)

Single flash repeating

The SLM cannot communicate
with any one of its paired ELMs

Fault LED (middle)

Double flash repeating

The connection to one or more
ELMs is too slow (a one-way
latency of more than 20 ms).
Refer to “Troubleshooting” on
page 14.

Encryption LED
(bottom)

Flashing for 4 seconds,
then repeating after two
seconds

The module is in pairing mode
(SW2 ON)

Encryption LED
(bottom)

Single flash repeating
(twice per second)

Pairing to all ELMs is complete
(SW2 ON)

Encryption LED
(bottom)

On constantly

Normal operation, pairing
completed (SW2 OFF)

Table 2: Mode, fault, encryption LED indications for an ELM

LED

Activity

Indication

Mode LED (top)

Single flash repeating
(twice per second)

ELM mode (SW1 OFF)

Fault LED (middle)

Single flash repeating

The ELM cannot communicate
with its paired SLM

CONCEPT

Summary of Contents for ATS1745

Page 1: ...ATS1745 Advisor Master IP Bus adaptor installation Setup Guide P N XXXXXXX EN REV A ISS 29JUL15 Preliminary manual not for sales C O N C E P T ...

Page 2: ... version Vxx Certification European Union directives UTC Fire Security hereby declares that this device is in compliance with the applicable requirements and provisions of one or more of the Directives 1999 5 EC 2014 30 EU and 2014 35 EU For more information see www utcfireandsecurity com or www interlogix com 2002 96 EC WEEE directive Products marked with this symbol cannot be disposed of as unso...

Page 3: ...745 modules 5 Connecting the ATS1745 module 6 System setup 7 Requirements 7 Setup overview 7 Programming assigned network parameters 8 Enabling communications 9 Updating firmware 9 Using the ATS1745 Web interface 11 Logging in 11 Logging out 11 Configuring devices 12 Managing users 13 Performing diagnostics 13 Troubleshooting 14 High latency faults 14 Checking network performance 14 Problems viewi...

Page 4: ...ndorse or promote products derived from this software without specific prior written permission THIS SOFTWARE IS PROVIDED BY THE AUTHOR AS IS AND ANY EXPRESS OR IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT INDIRECT INCIDENTAL SPECIAL EXEMPLARY OR CO...

Page 5: ...ornia by American Telephone and Telegraph Co or Unix System Laboratories Inc and are reproduced herein with the permission of UNIX System Laboratories Inc Redistribution and use in source and binary forms with or without modification are permitted provided that the following conditions are met 1 Redistributions of source code must retain the above copyright notice this list of conditions and the f...

Page 6: ...d distribute this software provided this notice is not removed or altered All other rights are reserved by SuperH SUPERH MAKES NO WARRANTY OF ANY KIND EXPRESS OR IMPLIED WITH REGARD TO THIS SOFTWARE IN NO EVENT SHALL SUPERH BE LIABLE FOR INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL SuperH Inc 405 River Oaks Parkway San Jose CA 95134 USA 13 Royal Institute of Technology Copyright c 1999 Kungliga Te...

Page 7: ...S SOFTWARE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE 20 DJ Delorie i386 Copyright C 1991 DJ Delorie All rights reserved Redistribution and use in source and binary forms is permitted provided that the above copyright notice and following paragraph are duplicated in all such forms 21 Free Software Foundation LGPL License linux targets only Copyright C 1990 1999 2000 2001 Free Software Found...

Page 8: ...DATA OR PROFITS OR BusINESS INTERRUPTION HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY WHETHER IN CONTRACT STRICT LIABILITY OR TORT INCLUDING NEGLIGENCE OR OTHERWISE ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE iconv Charset Conversion Library v2 0 27 Artem Bityuckiy enable newlib iconv Copyright c 2003 Artem B Bityuckiy SoftMine Corporation ...

Page 9: ...e IP connections to each Bus s RASs and DGPs Note An Advisor Master panel can have 16 RASs and 15 DGPs on its Bus The maximum number of ELMs is 31 ATS1745 modules have an onboard Web server that is used by installers to configure the module via a Web browser For security purposes a module s Web server can be locked to prevent unauthorized access ATS1745 modules are not polled as bus devices they a...

Page 10: ... section for details about setting up an ATS1745 module Figure 4 ATS1745 Advisor Master IP Bus Adaptor general layout ATS Master ATS Master system or local databus ATS Master 1 4 5 6 7 8 9 2 3 1 RJ 45 Ethernet port 2 RS 232 port firmware update 3 RS 485 ATS Bus 4 ATS bus termination 5 LED Red transmit data 6 LED Yellow receive data 7 DIP switch configuration 8 LEDs Mode Fault Encryption 9 Configur...

Page 11: ...sh repeating The SLM cannot communicate with any one of its paired ELMs Fault LED middle Double flash repeating The connection to one or more ELMs is too slow a one way latency of more than 20 ms Refer to Troubleshooting on page 14 Encryption LED bottom Flashing for 4 seconds then repeating after two seconds The module is in pairing mode SW2 ON Encryption LED bottom Single flash repeating twice pe...

Page 12: ...antly Normal operation pairing completed SW2 OFF DIP switch The four segment DIP switch Figure 4 item 7 on page 2 controls the following settings SW1 is OFF for an ELM or ON for an SLM SW2 is OFF for normal operating mode or ON for pairing mode SW3 is OFF for Web programming mode or ON for lock mode SW4 is OFF for normal operating mode or ON for firmware update mode Web interface ATS1745 modules h...

Page 13: ... trained in security and electrical industry installation regulations as appropriate to this device Installing ATS1745 modules ATS1745 modules may be set up prior to installation if desired See System setup on page 7 To install the ATS1745 module 1 Determine whether the module is to be an ELM or an SLM the default configuration is ELM 2 If the module is to be an SLM set SW1 to ON Figure 4 item 7 o...

Page 14: ...100 mA 13 8 V and may be powered from the Advisor Master panel s or Four Door Controller s Bus at J11 or from an external power supply The Advisor Master panel or Four Door Controller may be used to power the module in the following circumstances The Bus cabling distance to the module is no more than 50 m Electrical isolation is not required If powering the module from the Advisor Master panel or ...

Page 15: ...res that you know the following values for each module as assigned by the network administrator IP address Gateway address Netmask Port number If needed use Network assignments worksheet on page 18 to list the details for each module In order to preconfigure all modules at one location you will also need a computer on the same network as the ATS1745 modules at their assigned IP addresses and Ether...

Page 16: ...dule to identify its role SLM and its IP address until the module is installed To program each ELM s assigned network parameters 1 Select an ATS1745 module with SW1 in the OFF position Figure 4 item 7 on page 2 2 Connect power and Ethernet cables to the module Figure 4 on page 2 3 Start Internet Explorer on a computer connected to the network type 192 168 20 105 in the address bar and then press E...

Page 17: ...for two seconds and repeats this cycle When the pairing process is complete the encryption LED blinks every second 4 After the encryption LED indicates that pairing is complete typically three seconds move the ELM s SW2 to OFF 5 On the SLM move SW2 to OFF 6 Log in to the SLM s Web interface See Logging in on page 11 7 In the SLM s Device Configuration window look at the ELM s IP address Figure 8 o...

Page 18: ... 2 on page 2 to the computer s COM port 6 Start HyperTerminal and open a connection to the Comm port with 115200 bits per second 8 N 1 HyperTerminal should say waiting for upgrade with a few CCCC on screen 7 Select Send File from the Transfer menu Select IK Xmodem as the Protocol and then browse to select the supplied firmware file 8 Click Send HyperTerminal opens a Send File window and indicates ...

Page 19: ...work Figure 7 ATS1745 login window Logging in Log in with the default user name admin and the default password password Note The default password must be changed to keep unauthorised persons from viewing or modifying your programming See Managing users on page 13 After logging in you will see a Device Configuration window which varies depending on the ATS1745 module s role Figure 8 on page 12 The ...

Page 20: ...ing Remove an unneeded ELM s details to provide space for a new ELM or the same ELM at a new IP address Use the ELM s Device Configuration window to Program the ELM s assigned network parameters under the Host heading Program the SLM s assigned network parameters under the Remote heading Display the IP address pairing encryption status and connection status of the SLM The SLM Device Configuration ...

Page 21: ...o the SLM but a high latency condition is detected This IP Bus cannot carry Advisor Master data until the fault is resolved and the LED is green Refer to Troubleshooting on page 14 Managing users All ATS1745 modules are shipped with one default user named admin with password password User names and passwords are case sensitive and must be entered correctly Note The default password for admin must ...

Page 22: ... network performance below Troubleshooting high latency faults If a high latency condition exists before installation or develops after installation consider the following options Ensure you are using a fast Bus or WAN connection Avoid the use of dial up microwave or other network links that may increase latency Avoid congested high traffic routers or hubs Reduce the number of routers or hubs betw...

Page 23: ... the same router then you don t need to use the Advisor Master IP Bus Adaptor Network Tester for those modules there shouldn t be any latency and ATS1745 modules shouldn t experience any poll errors In the following steps we ll assume you are testing the network prior to installing the Advisor Master IP Bus system and the testing computer is located on the SLM side of the network If more convenien...

Page 24: ...at you have entered an invalid address in the Host field the host isn t sending ping replies or a firewall on the network is blocking ping requests Seek assistance from the network administrator if needed Problems viewing ATS1745 Web pages In order to view an ATS1745 module s Web pages You must use a compatible Web browser such as Internet Explorer 6 or later or Mozilla Firefox The module s SW2 SW...

Page 25: ...y press the Ctrl and F5 keys If you still cannot see the login window close and restart the Web browser If unsuccessful see Problems viewing ATS1745 Web pages on page 16 Resetting the ATS1745 module ATS1745 modules are shipped with the following default settings IP address 192 168 20 100 for an SLM or 192 168 20 105 for an ELM determined by the setting of SW1 Gateway 0 0 0 0 Netmask 255 255 255 0 ...

Page 26: ...C O N C E P T ...

Page 27: ... needed to list the assigned network details for ATS1745 Advisor Master IP Bus Adaptor modules Role IP Address Gateway address Netmask Port number SLM ELM1 ELM2 ELM3 ELM4 ELM5 ELM6 ELM7 ELM8 ELM9 ELM10 ELM11 ELM12 ELM13 ELM14 ELM15 ELM16 ELM17 ELM18 ELM19 ELM20 ELM21 ELM22 ELM23 ELM24 ELM25 ELM26 ELM27 ELM28 ELM29 ELM30 ELM31 C O N C E P T ...

Reviews: