background image

Figure 7: Set IP address screen 

 

3.  Repeat Step 2 to check if the IP address is changed. 

If the IP is successfully configured, the Managed Industrial Switch will apply 
the new IP address setting immediately. You can access the Web interface 
of Managed Industrial Switch through the new IP address. 

Note: 

If you are not familiar with console command or the related parameter, 

enter "?" anytime in console to get the help description. 

Telnet Setup 

1.  Connect an RJ-45 cable from the PC to a Switch port on the Managed 

Switch. 

8 of 13 

P/N 1069666-EN • REV 1.01 • ISS 14JUL10 

Summary of Contents for GE-DSH-82-PoE

Page 1: ...Port Gigabit TP SFP Combo Managed Switch The following Managed Switch model numbers are covered in this sheet GE DSH 73 GE DSH 82 GE DSH 82 PoE Open the box of the Managed Switch and carefully unpack it The box should contain the following items The Managed Switch x1 User manual CD x1 This Installation Sheet x1 RJ 45 to RS 232 cable x1 If any item is found missing or damaged please contact your lo...

Page 2: ...B 9 Ethernet Port connection Network cables Use standard network UTP cables with RJ45 connectors Above PC installed with WEB Browser and JAVA runtime environment Plug in Note We recommend using Windows XP or Windows 7 with Internet Explorer 6 0 or above for access to the switch management setup Wiring the Power Units The 6 contact terminal block connector on the top panel of Managed Industrial Swi...

Page 3: ...3 4 5 6 Power 2 Power 2 Note The wire gauge for the terminal block should be in the range between 12 to 24 AWG For the GE DSH 82 PoE A 48VDC 3A power input is required for full PoE load on the PoE Please connect an external power source to the terminal block that can supply steady power at 48VDC P N 1069666 EN REV 1 01 ISS 14JUL10 3 of 13 ...

Page 4: ...l Modem Figure 3 Terminal setup diagram Managed Industrial Switch RJ 45 Type Serial Port 9600 8 n 1 PC Workstation with Terminal emulation software 1 RJ 45 to DB9 RS 232 cable 2 Serial port A terminal program is required to make the software connection to the GE DSH 73 GE DSH 82 and the GE DSH 82 PoE Managed Switch Window s Hyper Terminal program is a good choice Hyper Terminal program can be acce...

Page 5: ...ted to the device power on the GE DSH 73 GE DSH 82 and the GE DSH 82 PoE Managed Switch The terminal will display that it is running testing procedures Then the following message asks for the login user name and password The factory default password for the login screen is Username admin Password admin P N 1069666 EN REV 1 01 ISS 14JUL10 5 of 13 ...

Page 6: ...ipped with default IP address as follows IP Address 192 168 0 100 Subnet Mask 255 255 255 0 To check the current IP address or modify a new IP address for the Managed Industrial Switch please use the procedures as follows Show the current IP address 1 On the Switch prompt enter enable to enter Privileged EXEC mode 2 On the Switch prompt enter show ip 3 The screen displays the current IP address Su...

Page 7: ...h config prompt enter the following command and press Enter As show in Figure 7 Switch config ip address 192 168 1 100 255 255 255 0 192 168 1 1 The previous command will apply the follow settings for the Managed Industrial Switch IP 192 168 1 100 Subnet Mask 255 255 255 0 Gateway 192 168 1 1 P N 1069666 EN REV 1 01 ISS 14JUL10 7 of 13 ...

Page 8: ...ddress setting immediately You can access the Web interface of Managed Industrial Switch through the new IP address Note If you are not familiar with console command or the related parameter enter anytime in console to get the help description Telnet Setup 1 Connect an RJ 45 cable from the PC to a Switch port on the Managed Switch 8 of 13 P N 1069666 EN REV 1 01 ISS 14JUL10 ...

Page 9: ...s Hyper Terminal program is a good choice Hyper Terminal can be accessed from the Start menu Click START then Programs Accessories and then Hyper Terminal 3 The following screen will appear Enter a new connection name You should use something like the model name of your switch Figure 9 New Connection dialog window 4 Change the Connect using drop down menu to TCP IP Winsock then input Host address ...

Page 10: ... Make sure the device has finished booting Once the telnet has connected to the device the hyper terminal will display the login request Then the following message asks the login user name and password The factory default password and the login screen are as follows User name admin Password admin 10 of 13 P N 1069666 EN REV 1 01 ISS 14JUL10 ...

Page 11: ...ed Switch Please note that the Managed Switch is configured through an Ethernet connection Make sure the manager PC is set on the same IP subnet address For example the default IP address of the GE DS 82 Managed Switch is 192 168 0 100 then the manager PC should be set at 192 168 0 x where x is a number between 1 and 254 except 100 and the default subnet mask is 255 255 255 0 P N 1069666 EN REV 1 ...

Page 12: ...r Enter the IP address http 192 168 0 100 the factory default IP address or that you have just changed in the console to access the Web interface 2 When the following dialog box appears please enter the default password admin or the password you have changed via console The login screen in Figure 13 appears Default IP Address 192 168 0 100 Default Username admin Default Password admin 12 of 13 P N...

Page 13: ...can browse our online FAQ resource at the Interlogix website first to check if it could solve your issue If you need more support information please contact our Interlogix support team 888 437 3287 Toll free in the US Puerto Rico and Canada 503 885 5700 outside of the toll free area For contact information see our Web site www interlogix com Copyright 2011 UTC Fire Security Contents subject to cha...

Reviews: