Authentication Method
Authentication Method can be set to one of the following values:
None
: authentication is disabled and login is not possible.
local
: use the local user database on the switch for authentication.
radius
: use a remote RADIUS server for authentication.
: use a remote server for authentication.
Fallback
Enable fallback to local authentication by checking this box.
If none of the configured authentication servers are alive, the local user database
is used for authentication.
This is only possible if the Authentication Method is set to something else than
'none or 'local'.
Buttons
: Click to save changes.
: Click to undo any changes made locally and revert to previously saved values.
4.11.3 Network Access Server Configuration
This page allows you to configure the IEEE 802.1X and MAC-based authentication system and port settings.
The IEEE 802.1X standard defines a port-based access control procedure that prevents unauthorized access to a network by
requiring users to first submit credentials for authentication. One or more central servers, the backend servers, determine
whether the user is allowed access to the network. These backend (RADIUS) servers are configured on the
"Configuration
→
Security
→
AAA" page. The IEEE802.1X standard defines port-based operation, but non-standard variants
overcome security limitations as shall be explored below.
MAC-based authentication allows for authentication of more than one user on the same port, and doesn't require the user to have
special 802.1X supplicant software installed on his system. The switch uses the user's MAC address to authenticate against the
backend server. Intruders can create counterfeit MAC addresses, which makes MAC-based authentication less secure than
802.1X authentication. The NAS configuration consists of two sections, a system- and a port-wide. The Network Access Server
Configuration screen is shown in
Figure 4-11-4
.
Summary of Contents for IFS NS3550-24T/4S
Page 1: ...P N 1072569 REV 00 05 ISS 11OCT12 IFS NS3550 24T 4S User Manual ...
Page 37: ...User s Manual of NS3550 24T 4S 37 ...
Page 96: ...96 Figure 4 4 6 Port Mirror Configuration Page Screenshot ...
Page 127: ...User s Manual of NS3550 24T 4S 127 Figure 4 6 10 Port 1 Port 6 VLAN Configuration ...
Page 184: ...184 Figure 4 9 14 Voice VLAN Configuration Page Screenshot ...
Page 204: ...204 Figure 4 11 4 Network Access Server Configuration Page Screenshot ...
Page 234: ...234 Figure 4 12 1 Port Limit Control Configuration Overview Page Screenshot ...
Page 250: ...250 Click to undo any changes made locally and revert to previously saved values ...
Page 297: ...User s Manual of NS3550 24T 4S 297 ...
Page 388: ...388 Example Show RADIUS statistics SWITCH security aaa statistics ...
Page 410: ...410 Parameters vid VLAN ID 1 4095 Default Setting disable ...