User’s Manual of NS3550-24T/4S
273
4.15 Network Diagnostics
This section provide the Physical layer and IP layer network diagnostics tools for troubleshooting. The diagnostic tools are
designed for network manager to help them quickly diagnose problems between point to point and better service customers.
Use the Diagnastics menu items to display and configure basic administrative details of the Managed Switch. Under System the
following topics are provided to configure and view the system information:
This section has the following items:
Ping
IPv6 Ping
Cable Diagnostic
PING
The ping and IPv6 ping allow you to issue ICMP PING packets to troubleshoot IP connectivity issues. The Managed Switch
transmit ICMP packets, and the sequence number and roundtrip time are displayed upon reception of a reply.
Cable Diagnostics
The Cable Diagnostics perform tests on copper cables. These functions have the ability to identify the cable length and operating
conditions, and to isolate a variety of common faults that can occur on the Cat5 twisted-pair cabling. There might be two status as
follow:
If the link is established on the twisted-pair interface in 1000Base-T mode, the Cable Diagnostics can run without
disruption of the link or of any data transfer.
If the link is established in 100Base-TX or 10Base-T, the Cable Diagnostics cause the link to drop while the diagnostics
are running.
After the diagnostics are finished, the link is reestablished. And the following functions are available.
Coupling between cable pairs.
Cable pair termination
Cable
Length
Buttons
: Click to start to transmit ICMP packets.
4.15.1 Ping
This page allows you to issue ICMP PING packets to troubleshoot IP connectivity issues.
After you press “
Start
”, 5 ICMP packets are transmitted, and the sequence number and roundtrip time are displayed upon
reception of a reply. The page refreshes automatically until responses to all packets are received, or until a timeout occurs. The
Summary of Contents for IFS NS3550-24T/4S
Page 1: ...P N 1072569 REV 00 05 ISS 11OCT12 IFS NS3550 24T 4S User Manual ...
Page 37: ...User s Manual of NS3550 24T 4S 37 ...
Page 96: ...96 Figure 4 4 6 Port Mirror Configuration Page Screenshot ...
Page 127: ...User s Manual of NS3550 24T 4S 127 Figure 4 6 10 Port 1 Port 6 VLAN Configuration ...
Page 184: ...184 Figure 4 9 14 Voice VLAN Configuration Page Screenshot ...
Page 204: ...204 Figure 4 11 4 Network Access Server Configuration Page Screenshot ...
Page 234: ...234 Figure 4 12 1 Port Limit Control Configuration Overview Page Screenshot ...
Page 250: ...250 Click to undo any changes made locally and revert to previously saved values ...
Page 297: ...User s Manual of NS3550 24T 4S 297 ...
Page 388: ...388 Example Show RADIUS statistics SWITCH security aaa statistics ...
Page 410: ...410 Parameters vid VLAN ID 1 4095 Default Setting disable ...