2.2.4 Wiring the Power Input
The 6-contact terminal block connector on the rear panel of NS3550-24T/4S is used for two DC redundant powers inputs. Please
follow the steps below to insert the power wire.
1.
Insert positive / negative DC power wires into the contacts 1 and 2 for DC POWER 1, or 5 and 6 for DC POWER 2.
Figure 2-9
Wiring the Redundant Power Inputs
2.
Tighten the wire-clamp screws to prevent the wires from loosening.
1 2 3 4 5 6
DC 2
DC 1
+ - + -
Figure 2-10
6-Pin Terminal Block Power Wiring Input
The wire gauge for the terminal block should be in the range between 12 ~ 24 AWG.