background image

© 01/01/19 UTC Fire & Security. All rights reserved. 

1 / 14 

P/N 466-5519 • REV 0.01 • 24MAY19 

24VAC or Battery Powered Z-Wave Thermostat 
Installation/User Guide 

Content

Description ........................................................................................ 1

Battery Powered Operation ............................................................... 1

Installation Steps ............................................................................... 2

Remove old thermostat ..................................................................... 2

Heat Pump HVAC Systems Wiring ................................................... 3

Mount the thermostat ........................................................................ 3

Standard Gas/Electric HVAC System Wiring .................................... 5

Heat Pump HVAC System Wiring ..................................................... 6

Thermostat Setup: Configure for HVAC System ............................... 7

Changing the HVAC System Setup .................................................. 7

Menu Options .................................................................................... 7

Advanced System Settings Menu ..................................................... 8

Advanced Settings ............................................................................ 8

Operation ........................................................................................ 10

Backlight and Button Operation ...................................................... 10

Thermostat Backlight Display.......................................................... 10

Setpoint Change ............................................................................. 11

Fan Modes ...................................................................................... 11

Thermostat Menu Mode .................................................................. 12

Menu Mode Options ........................................................................ 12

Thermostat Operation ..................................................................... 13

Minimum Run Time (MRT) .............................................................. 13

Minimum off Time (MOT) ................................................................ 13

Z-Wave

®

 Operation ......................................................................... 13

FCC Compliance ............................................................................. 14

Contact Information 

For contact information, see

www.utcfireandsecurity.com

or

www.interlogix.com. 

For technical support, toll-free: 888.437.3287 / 855.286.8889 

in the US including Alaska, Hawaii, Puerto Rico, and 

Canada.  

Outside toll-free area, contact your dealer. 

© 2019 UTC Fire & Security Americas Corporation, Inc. 

Interlogix is part of UTC Climate Controls & Security, a unit 

of United Technologies Corporation.  

All rights reserved. 

Safety Information 

WARNING: CHOKING 

HAZARD. 

The product accessory bag 

contains items that could be choking hazards. Please 

keep away from small children. 

AVERTISSEMENT: 

Le sachet de produits accessoires contient des 

éléments qui pourrait présenter un danger 

d’étouffement. Veuillez garder hors de la 

portée des jeunes enfants. 

Description 

This thermostat is compatible with most HVAC systems, 

including the following: 

x

 

24VAC systems   

Note:

  Requires both the 24VAC R and C (“common”) wires unless 

battery powered. 

x

 

Standard gas/oil/electric heating systems   

™

  1 stage heating and cooling 

™

  2 stage heating and cooling 

x

 

Heat Pump systems: 

™

  1 stage heating and cooling 

™

  2 stage heating and cooling 

™

  2

nd

 or 3

rd

 stage Auxiliary heating (heat strips)  

Warning! 

Do

NOT

 use for line voltage controls 

(120/240VAC)

The thermostat can either be powered by batteries or 

24VAC.

Battery Powered Operation 

The thermostat can be powered by four AA Alkaline 

batteries. The thermostat will operate for approximately two 

years on four AA Alkaline batteries depending on the 

frequency of user operations and backlight operation. 

Always use alkaline batteries and replace all four at the 

same time with 

NEW

 batteries. 

Summary of Contents for IS-ZW-TSTAT-500

Page 1: ... Inc Interlogix is part of UTC Climate Controls Security a unit of United Technologies Corporation All rights reserved Safety Information WARNING CHOKING HAZARD The product accessory bag contains items that could be choking hazards Please keep away from small children AVERTISSEMENT Le sachet de produits accessoires contient des éléments qui pourrait présenter un danger d étouffement Veuillez garde...

Page 2: ...he wires attached to the terminals with the wiring labels included 3 Use the terminal labels and not the wiring color to mark the wires 4 Remove the old thermostat base CAUTION Don t let the wires slip into the wall Figure 1 Thermostat Wiring Note The C wire 24V common may not be present If C wire is not present the thermostat must be powered by batteries ATTENTION If the C wire is present you can...

Page 3: ...d cooling systems with separate 24VAC transformers For those systems there will be a separate R wire for the heating system RH and cooling system transformers RC To connect separate transformer systems FIRST REMOVE THE SUPPLIED RH RC JUMPER Then connect the heating R wire to the RH terminal and the cooling R wire to the RC terminal on the thermostat Heat Pump HVAC Systems Wiring Figure 3 Single st...

Page 4: ...Powered Thermostat 1 Install the thermostat on to the base 2 Turn on power to the HVAC system thermostat x Battery Powered Thermostat If the thermostat is battery powered NO 24VAC common C wire connected install 4 NEW Alkaline AA batteries into the back of the thermostat Figure 5 Battery Powered Thermostat 1 Install the thermostat on to the base 2 Turn on power to the HVAC system thermostat ...

Page 5: ...pical gas furnace fan is controlled by the furnace x Set to ELECTRIC for electric heat fan on with heat call For Two Stage Heat Cool Systems Go to ADVANCED SYSTEMS SETTINGS menu From the Setup menu screen press and hold the Fan button and Down arrow buttons for 5 seconds Use the Down arrow button to select the following x 2nd Stage Heat Enable Enable second stage heating output If a single stage h...

Page 6: ... and holding the FAN button for 5 seconds 2 Press the down arrow to select the SYSTEM menu and press Select Set the following x System Type Set to HEAT PUMP x Change Over For changeover with cooling systems Orange wire set to WITH COOL most common and default setting For changeover with heating systems Brown wire set to WITH HEAT You must configure the thermostat s changeover valve setting to work...

Page 7: ...AC system the System setup does not need to be changed Installation is complete For thermostats installed on a Heat Pump HVAC system or any HVAC configuration other than the preset settings the System settings need to be changed in the SYSTEM setup menu to match the HVAC system Changing the HVAC System Setup To change the thermostats HVAC system settings first select the Menu Screen and then selec...

Page 8: ...system x Set the Change Over setting accordingly CAUTION These are typical wiring colors connections and may differ x If heating comes on when cooling is expected or vice versa change the Change Over Type to the opposite setting Advanced System Settings Menu The Advanced System Settings Menu provides for addition system setup options These settings can affect system operation and should only be ch...

Page 9: ...nued Setpoint Push x Attempts to lower the cooling setpoint below the heating setpoint will PUSH the heating setpoint down to maintain the heat cool delta separation x Attempts to set the heating setpoint above the cooling setpoint will PUSH the cooling setpoint up to maintain the setpoint heat cool delta separation Heating Stage 1 On Threshold Range 1 to 6 Default 1 Sets the delta from setpoint t...

Page 10: ...ostat Backlight Display IS ZW TSTAT 500 Table 2 System Operation Modes Icon Description System is ON and heating If flashing minimum run time MRT is active System is ON and cooling If flashing minimum run time MRT is active LLOW BATTY Battery indicator Display lock indicator Z Wave network indicator Stage Indicators x 1 Stage 1 heating or cooling is ON x 2 Stage 2 heating or cooling is ON x 3 Stag...

Page 11: ...the Up or Down arrow buttons The screen will switch to the setpoint change screen as above and show the current setpoint of the current heating or cooling mode Adjust setpoint temperature up or down with the arrow buttons Note When in the Setpoint Change screen pressing the MODE button will switch the setpoint being displayed between the Heat and Cool setpoints x Setpoint Push The cooling setpoint...

Page 12: ...ired temperature displayed x Humidity Sensor Calibration Change the humidity calibration by 7 Use the Up Down arrow buttons to change to the desired humidity displayed x Status Line display Select Setpoints or Humidity to be displayed on the upper status line System Menu x System type Select the system type Standard or Heat Pump Fan type standard systems only x Select fan type Gas typical default ...

Page 13: ...d as an always listening device and can act as a router node in the Z Wave network CAUTION Once installed in a Z Wave network if you change how the thermostat is powered from batteries to 24VAC or vice versa you must remove and re enroll the thermostat in the Z Wave network for it to work correctly Adding the thermostat to a Z Wave network 3 Follow the instructions provided with your system for en...

Page 14: ...the user is encouraged to try to correct the interference by one or more of the following measures x Reorient or relocate the receiving antenna x Increase the separation between the equipment and receiver x Connect the equipment into an outlet on a circuit different from that to which the receiver is connected x Consult the dealer or an experienced radio TV technician for help Any changes or modif...