8-Port 10/100/1000Mbps Industrial Gigabit 
Ethernet Switch - NS3050-8P - User Manual 

Package Contents

 

 

Thank you for purchasing IFS 8-Port 10/100/1000T industrial 
Gigabit Ethernet Switch, NS3050-8T. In the following section, 
the term “

Industrial Gigabit Ethernet Switch

” means the 

NS3050-8T. 

Open the box of the Industrial Gigabit Ethernet Switch and 
carefully unpack it. The box should contain the following items: 

 

Industrial Gigabit Ethernet 
Switch x 1 

 

User's Manual x 1 

 

 

 

 

DIN Rail Kit x 1 

 

Wall-mount Kit x 1 

 

If any of these are missing or damaged, please contact your 
dealer immediately; if possible, retain the carton including the 
original packing material, and use them again to repack the 
product in case there is a need to return it to us for repair. 

2. Hardware Introduction 

2.1 Physical Dimensions 

NS3050-8T dimensions (W x D x H): 135 x 87 x 32mm  

See Figure 2.1 on page 6. 

2.2 Switch Front Panel 

The front panel of the Industrial Gigabit Ethernet Switch 
consists of 5 or 8 auto-sensing 10/100/1000Mbps Ethernet 
RJ45 ports. The LED Indicators are also located on the RJ45 
ports of the Gigabit Ethernet Switch. 

Figures 2-2 show the front panels of Industrial Gigabit Ethernet 
Switches. 

Figure 2-2: NS3050-8T Front Panel  

 

 

 

 

 

 

 

 

 

 

2.3 LED Indicators 

 

LED 

Color 

Function 

P1 

Green 

Lit

: indicates power 1 has power. 

P2 

Green

 

Lit

: indicates power 2 has power. 

FAULT 

Red 

Lit: indicates either power 1 or power 2 has no 
power. 

(See Note: 1)

 

1000 

Green 

Lit

: indicates the port is successfully 

connecting to the network at 1000Mbps. 

Off: indicates that the port is successfully 
connecting to the network at 10Mbps or 
100Mbps. 

Blinking

: indicates that the port is actively 

sending or receiving data. 

100 

Orange 

Lit

: indicates the port is successfully 

connecting to the network at 100Mbps or 
10Mbps. 

Off

: indicates that the port is successfully 

connecting to the network at    1000Mbps. 

Blinking: indicates that the port is actively 
sending or receiving data. 

 

(Note: 1) Notice the fault light will go out if you tie power 1 to 
power 2 if you are not using redundant power. 

 

Summary of Contents for NS3050-8T

Page 1: ...x D x H 135 x 87 x 32mm See Figure 2 1 on page 6 2 2 Switch Front Panel The front panel of the Industrial Gigabit Ethernet Switch consists of 5 or 8 auto sensing 10 100 1000Mbps Ethernet RJ45 ports The LED Indicators are also located on the RJ45 ports of the Gigabit Ethernet Switch Figures 2 2 show the front panels of Industrial Gigabit Ethernet Switches Figure 2 2 NS3050 8T Front Panel 2 3 LED In...

Page 2: ...input range is 12V 48 VDC 2 6 Wiring the Fault Alarm Contact The fault alarm contacts are in the middle of the terminal block connector as the picture shows below Inserting the wires the Industrial Gigabit Ethernet Switch will detect the fault status of the power failure and then forms an open circuit The following illustration shows an application example for wiring the fault alarm contacts 1 2 3...

Page 3: ...wall mount application with DIN rail application on Industrial Gigabit Ethernet Switch please refer to the following figures to screw the DIN rail on the Industrial Gigabit Ethernet Switch To hang the Industrial Gigabit Ethernet Switch please follow the steps below Step 1 Screw the DIN rail on the Industrial Gigabit Ethernet Switch Step 2 Place the bottom of DIN rail lightly into the track Step 3 ...

Page 4: ...duplex Some devices use a physical or software switch to change duplex modes Auto negotiation may not recognize this type of full duplex setting The Industrial Gigabit Ethernet Switch doesn t connect to the network Solution Check per port LED on the Industrial Gigabit Ethernet Switch Try another port on the Industrial Gigabit Ethernet Switch Make sure the cable is installed properly Make sure the ...

Page 5: ...ice may not cause harmful interference 2 This Device must accept any interference received including interference that may cause undesired operation ACMA compliance Notice This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Canada This Class A digital apparatus complies with CAN ICES 003 A NM...

Page 6: ...6 6 P N 1073226 REV A ISS 13SEP16 Physical Dimensions Figure 2 1 NS3050 8T dimensions W x D x H 135 x 87 x 32mm ...