Step 3: 

Use the screws to screw the wall-mount plate on the 

Industrial Gigabit Ethernet Switch. 

 

Step 4: 

Use the hook holes at the corners of the wall-mount 

plate to hang the Industrial Gigabit Ethernet Switch on the 
wall.

 

Step 5: 

To remove the wall-mount plate, reverse the steps 

above. 

4. TROUBLESHOOTING 

This chapter contains information to help you solve issues. If 
the Industrial Gigabit Ethernet Switch is not functioning 
properly, make sure the Industrial Gigabit Ethernet Switch was 
set up according to instructions in this manual. 

The per port LED is not lit 

Solution

Check the cable connection of the Industrial Gigabit 
Ethernet Switch. 

Performance is bad 

Solution: 

Check the speed duplex mode of the partner device. The 
Industrial Gigabit Ethernet Switch is run in auto-
negotiation mode and if the partner is set to half duplex, 
then the performance will be poor. 

Per port LED is lit, but the traffic is irregular 

Solution: 

Check that the attached device is not set to dedicate full 
duplex. Some devices use a physical or software switch to 
change duplex modes. Auto-negotiation may not 
recognize this type of full-duplex setting. 

The Industrial Gigabit Ethernet Switch doesn’t connect to 
the network  

Solution: 

Check per port LED on the Industrial Gigabit Ethernet 
Switch. Try another port on the Industrial Gigabit Ethernet 
Switch. Make sure the cable is installed properly. Make 

sure the cable is the right type. Turn off the power. After a 
few moments, turn on the power again. 

APPENDIX A: NETWORKING 
CONNECTION 

A.1 Switch’s RJ45 Pin Assignments 

 

1000Mbps, 1000BASE-T 

 

Contact 

MDI 

MDI-X 

BI_DA+ 

BI_DB+ 

BI_DA- 

BI_DB- 

BI_DB+ 

BI_DA+ 

BI_DC+ 

BI_DD+ 

BI_DC- 

BI_DD- 

BI_DB- 

BI_DA- 

BI_DD+ 

BI_DC+ 

BI_DD- 

BI_DC- 

 

10/100Mbps, 10/100BASE-TX 

 

RJ45 Connector pin assignment 

Contact 

MDI 

Media Dependent 
Interface 

MDI-X 

Media Dependent 
Interface -Cross 

Tx + (transmit) 

Rx + (receive) 

Tx - (transmit) 

Rx - (receive) 

Rx + (receive) 

 Tx + (transmit) 

4, 5 

Not used 

Rx - (receive) 

 Tx - (transmit) 

7, 8 

Not used 

A.2 RJ45 Cable Pin Assignments 

 

The standard RJ45 receptacle/connector 

There are 8 wires on a standard UTP/STP cable and each wire 
is color-coded. The following shows the pin allocation and color 
of straight-through cable and crossover cable connection: 

 

Summary of Contents for NS3050-8T

Page 1: ...x D x H 135 x 87 x 32mm See Figure 2 1 on page 6 2 2 Switch Front Panel The front panel of the Industrial Gigabit Ethernet Switch consists of 5 or 8 auto sensing 10 100 1000Mbps Ethernet RJ45 ports The LED Indicators are also located on the RJ45 ports of the Gigabit Ethernet Switch Figures 2 2 show the front panels of Industrial Gigabit Ethernet Switches Figure 2 2 NS3050 8T Front Panel 2 3 LED In...

Page 2: ...input range is 12V 48 VDC 2 6 Wiring the Fault Alarm Contact The fault alarm contacts are in the middle of the terminal block connector as the picture shows below Inserting the wires the Industrial Gigabit Ethernet Switch will detect the fault status of the power failure and then forms an open circuit The following illustration shows an application example for wiring the fault alarm contacts 1 2 3...

Page 3: ...wall mount application with DIN rail application on Industrial Gigabit Ethernet Switch please refer to the following figures to screw the DIN rail on the Industrial Gigabit Ethernet Switch To hang the Industrial Gigabit Ethernet Switch please follow the steps below Step 1 Screw the DIN rail on the Industrial Gigabit Ethernet Switch Step 2 Place the bottom of DIN rail lightly into the track Step 3 ...

Page 4: ...duplex Some devices use a physical or software switch to change duplex modes Auto negotiation may not recognize this type of full duplex setting The Industrial Gigabit Ethernet Switch doesn t connect to the network Solution Check per port LED on the Industrial Gigabit Ethernet Switch Try another port on the Industrial Gigabit Ethernet Switch Make sure the cable is installed properly Make sure the ...

Page 5: ...ice may not cause harmful interference 2 This Device must accept any interference received including interference that may cause undesired operation ACMA compliance Notice This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Canada This Class A digital apparatus complies with CAN ICES 003 A NM...

Page 6: ...6 6 P N 1073226 REV A ISS 13SEP16 Physical Dimensions Figure 2 1 NS3050 8T dimensions W x D x H 135 x 87 x 32mm ...

Reviews: