94
Distance(m)
Display the supports distance of current SFP module, the distance value is get
from the SFP module.
Temperature(C)
– SFP DDM Module Only
Display the temperature of current SFP DDM module, the temperature value is
get from the SFP DDM module.
Voltage(V)
– SFP DDM Module Only
Display the voltage of current SFP DDM module, the voltage value is get from the
SFP DDM module.
Current(mA)
– SFP DDM Module Only
Display the Ampere of current SFP DDM module, the Ampere value is get from
the SFP DDM module.
TX power(dBm)
– SFP DDM Module Only
Display the TX power of current SFP DDM module, the TX power value is get
from the SFP DDM module.
RX power(dBm)
– SFP DDM Module Only
Display the RX power of current SFP DDM module, the RX power value is get
from the SFP DDM module.
Buttons
SFP Monitor Event Alert:
send trap
Warning Temperature:
degrees C
Check SFP Monitor Event Alert box; it will be in accordance with your warning temperature setting and allows users to record
message out via SNMP Trap.
Auto-refresh
: Check this box to enable an automatic refresh of the Page at regular intervals.
: Click to apply changes
: Click to undo any changes made locally and revert to previously saved values.
: Click to refresh the Page immediately.
4.4.5 Port Mirror
Configure port Mirroring on this Page. This function provide to monitoring network traffic that forwards a copy of each incoming or
outgoing packet from one port of a network Switch to another port where the packet can be studied. It enables the manager to keep
close track of switch performance and alter it if necessary.
To debug network problems, selected traffic can be copied, or mirrored, to a mirror port where a frame analyzer can be
attached to analyze the frame flow.
The Managed Switch can unobtrusively mirror traffic from any port to a monitor port. You can then attach a protocol analyzer or
RMON probe to this port to perform traffic analysis and verify connection integrity.
Summary of Contents for NS3702-24P-4S
Page 1: ...NS3702 24P 4S User Manual P N 1072832 REV 00 01 ISS 14JUL14 ...
Page 102: ...102 Figure 4 5 4 LACP Port Configuration Page Screenshot ...
Page 119: ...119 Figure 4 6 4 VLAN Membership Status for Static User Page Screenshot ...
Page 124: ...124 Figure 4 6 6 Private VLAN Membership Configuration page screenshot ...
Page 140: ...140 Figure 4 6 21 Group Name to VLAN Mapping Table Page Screenshot ...
Page 164: ...164 Figure 4 8 2 Multicast Flooding ...
Page 184: ...184 Figure 4 8 15 MLD Snooping Port Group Filtering Configuration Page Screenshot ...
Page 204: ...204 Figure 4 9 6 QoS Egress Port Tag Remarking Page Screenshot ...
Page 209: ...209 QoS Class QoS Class value can be any of 0 7 DPL Drop Precedence Level 0 1 ...
Page 251: ...251 Figure 4 11 3 Authentication Method Configuration Page Screenshot ...
Page 286: ...286 Figure 4 11 11 RADIUS Server Configuration Screenshot ...
Page 290: ...290 Figure 4 11 17 Add User Properties Screen Figure 4 11 18 Add User Properties Screen ...
Page 298: ...298 non committed changes will be lost ...
Page 349: ...349 Figure 4 16 2 PoE Configuration Screenshot ...