Switching points 

Details can be found at Figure 6. 

It is possible to adjust the switch point of the bolt contact with a 
locking disk on to the designated switch point. 

Set the switch point 1 until 4 with the tip of a screwdriver. Raise 
the locking disk on the notch and turn until it engages again. 

Schematic 

 Technical data 

 

Item No. 

RK100-N 

Contact termination 

3 soldered terminals 

Protection category 

IP50/DIN 40050; VdS environmental class II 

VdS Class 

VdS No 

G 110103 

Designated use 

For mounting on interior doors 

Contact capacity 

max. 3 W / VA 

Switch voltage 

max. 30 VDC 

Switch current 

min. 5 mA 

Switch current  

max. 300 mA 

Contact type 

Change over 

Temperature at fixed 
cable 

−25°C to +70°C 

Temperature at 
moveable cable 

−5°C to +50°C 

Switch point 

Adjustable 

Cycles of operation 

min. 30,000 

 

Regulatory information 

 

Manufacturer 

PLACED ON THE MARKET BY: 
UTC Fire & Security Americas Corporation, Inc. 
3211 Progress Drive, Lincolnton, NC, 28092, 
USA 

AUTHORIZED EU REPRESENTATIVE: 
UTC Fire & Security B.V. 
Kelvinstraat 7, 6003 DH Weert, Netherlands 

Certification 

    

 

Product warnings 
and disclaimers 

 

THESE PRODUCTS ARE INTENDED FOR 
SALE TO AND INSTALLATION BY QUALIFIED 
PROFESSIONALS. UTC FIRE & SECURITY 
CANNOT PROVIDE ANY ASSURANCE THAT 
ANY PERSON OR ENTITY BUYING ITS 
PRODUCTS, INCLUDING ANY “AUTHORIZED 
DEALER” OR “AUTHORIZED RESELLER”, IS 
PROPERLY TRAINED OR EXPERIENCED TO 
CORRECTLY INSTALL FIRE AND SECURITY 
RELATED PRODUCTS. 

For more information on warranty disclaimers and 
product safety information, please check 

https://firesecurityproducts.com/policy/product-
warning/

 or scan the QR code. 

European Union 
directives 

UTC Fire & Security hereby declares that this 
device is in compliance with the applicable 
requirements and provisions of the Directive 
2014/30/EU and/or 2014/35/EU. For more 
information see www.utcfireandsecurity.com or 
www.interlogix.com. 

 

2012/19/EU (WEEE directive): Products marked 
with this symbol cannot be disposed of as 
unsorted municipal waste in the European Union. 
For proper recycling, return this product to your 
local supplier upon the purchase of equivalent 
new equipment, or dispose of it at designated 
collection points. For more information see: 
www.recyclethis.info 

 

Contact information 

For more information visit our website: 
www.utcfireandsecurity.com. 

 

 

DE: Montageanleitung 

Montageort 

Der Riegelschaltkontakt ist zur Montage u.a. im 
Türschließblech zur Verschlussüberwachung der Verriegelung 
geeignet. Die Betätigung des Riegelschaltkontaktes erfolgt 
durch den Schloßriegel. Die Meldung kann für 
Einbruchmeldeanlagen und Überwachungssysteme 
ausgewertet bzw. angezeigt werden. 

Lieferumfang (siehe Abbildung 2) 

1.  Riegelschaltkontakt 

2. 

Hebelverlängerung (Kunststoff) 

3. 

Hebelverlängerung (Metall) 

4.  Kunststoffhalter 

5.  Blechschraube 2,2 x 4,5 

6.  Senkkopfschraube M3 x 6 

7.  Montageanleitung 

Abmessungen 

Siehe Abbildung 3. 