IPHOST=
This is the IP address or domain name of the Ethernet host. The value can be at
most 18 characters long. If this parameter specifies a domain name, the
IPCLIENT parameter must be omitted because DHCP information about
domain name servers is required to resolve the host name. For PSROM0C
V3.xx, if IPHOST and IPCLIENT are both omitted, the host name is retrieved
from DHCP if available. Otherwise, this parameter defaults to Norand6920."
MODEMSELECT=
Valid only if 2Ćway TTY protocol was specified. It is the modem ID of a record in
the modem table file NRTTYM.TBL. If this parameter is specified, the COM=
and CONFIG= parameters may be omitted. MODEMSELECT= and
MODEMTYPE= are mutually exclusive, that is, only one may be specified in a
control file.
Example:
MODEMSELECT=30
MODEMTYPE=
Valid only if twoĆway TTY protocol was specified. It indicates the type of modem,
if any, to which the HHC is connected:
Valid Values:
0 = No modem, i.e. direct connect (default)
1 = NORAND or other HayesĆcompatible modem
Example:
MODEMTYPE=1
NETMASK=
S
upported in PSROM0C V3.xx only.
This is the local subnet mask and is required if IPCLIENT is specified.
Example:
NETMASK=255.255.240.0
NPCPHOST=
The name of the NPCP host.
Valid values:
NORAND_HOST and NORAND_SERVER.
PARITY=
Valid only if twoĆway TTY protocol was specified.
Valid values:
0 = none (default)
1 = odd
2 = even
Example:
PARITY=2
PHONE=
Dials a HayesĆcompatible modem. This value can be at most 20 characters long.
Example:
PHONE=ATDT3693361
5. Communications