Uninterruptible Power Supply Instructions
Understanding the Power/Charge Status
LED
The LED lights when power is applied to the UPS.
• Amber: indicates UPS is charging
• Red: indicates UPS is discharging
• Green: indicates UPS is charged.
Using the Remote Sense Input (Optional,
CV60 Only)
This input can be used if you desire to manually force the UPS to
send a shutdown signal to the CV60 via the Primary Power Fail
and Low Battery lines. These two signals immediately cause the
CV60 to begin the shut down process. The UPS should be
configured in the Smart Mode for this operation. A switch/cable
assembly needs to be assembled and attached to this input to use
this capability.
To install the remote sense input
1
Cut the 2-pin connector end from the cable (P/N 226-340-
003) and wire the toggle switch as shown.
2
Install the cable into the 4-pin connector.
Note:
Always have power to the UPS before booting
the CV60. Failure to do so may cause the UPS to shut
down.