94
Intermec EasyCoder 201 II – Technical Manual
INTERFACES, cont'd.
Industrial Interface Board,
cont'd.
IN1
9
10
P-3
TIL193B
R5
R6
C10
Example of an IN port
Signal
Min.
Typical
Max.
Input Voltage High 10V
24V
40V
Input Voltage Low -1V
0V
1V
Example of an OUT port
+5V
1
2
P-3
REL1
1
OUT1
P-2
3 2
Max AC Load Breaking Capacity
Max. DC Load Breaking Capacity
1
0.5
0.1
10
20
30 40 50
100
DC Voltage (VDC)
a: resistive load
b: inductive load L/R=20 ms
DC current (A)
a
b
Current
max. 1 A
Switching power
max. 100VA AC
Switching voltage
max. 100V AC