Intermec EasyCoder 501 XP & 601 XP – Service Manual
205
Appendix 3 Firmware Upgrading
EasyLAN100i is a print server and can be added as an optional
board on EasyCoder 501 XP/601 XP. The print server firmware is
stored in a flash memory on this board.
1. Set a manual IP address from printers keyboard.
2. Start a DOS session and go to the map where the firmware is.
3. Here are the commands, each followed by Enter:
>ftp printer’s IP address
>User? root
>Password? pass
>hash
>bin
>put EL100i.bin FLASH
.
.
>bye
Example:
Upgrade firmware from version 6.10 to version 6.20.
IP adress at printer 198.168.0.2 (manual setting) and at computer
198.168.0.1.
C:\Firm620>ftp 192.168.0.2
Connected to 192.168.0.2
220 Intermec EasyLAN 100i FTP Print Server V6.10 Mar 30
2000 ready.
User (192.168.0.2:(none)): root
331 User name ok, need password
Password: pass
230 User logged in
ftp> hash
Hash mark printing On ftp: (2048 bytes/hash mark) .
ftp> bin
200 TYPE set to I.
ftp> put EL100i.BIN FLASH
200 PORT command successful.
150 Opening data connection for FLASH (192,168,0.1,4,9),
(mode binary).
################################################################################
################################################################################
################################################################################
################################################################################
################################################################################
################################################################################
################################################################################
##################
221-Transfer complete, flash programming finished OK.
Starting new software...
221 Reset, closing connection.
ftp: 1184408 bytes sent in 29,88Seconds 31,64Kbytes/sec.
ftp> bye
Upgrading EasyLAN
100i Firmware