Intermec EasyCoder 601 XP – Installation & Operation Ed. 3
Chapter 2 Print a Label
Setup
By default, the printer is set up for the following communication
protocol:
Baudrate ............................. :
9600
Character length ................. :
8
Parity .................................. :
none
Stop bits ............................. :
1
Flowcontrol ........................ :
none
New line ............................. :
CR/LF
If you want to change any of these values, please refer to chapter 8
“Setup Mode”.
Set up the terminal or host computer for the same communication
protocol as the printer.
Paper Supply
Load the printer with labels on backing paper (liner) with a width of
at least 35 mm (1.4") and a length of at least 40 mm (1.6") and a
thermal transfer ribbon, see chapters 5 and 6.
If the printout becomes too light or dark, you will need to change
the paper type setup, see chapter 8 “Setup Mode”.
Startup and Communications Check
Turn on the printer. Provided the printer is not fitted with any cus-
tom-made startup program, after initialization the display will show
the Intermec Shell countdown menu:
ENTER=SHELL
5 sec. v.4.2
4 sec. v.4.2
3 sec. v.4.2
2 sec. v.4.2
1 sec. v.4.2
Do not take any action. By default, the display window will show
the following message
when the countdown is completed, e.g.:
Fingerprint
7.12
If the display does not show this message, refer to chapter 9 “Inter-
mec Shell Startup Program” and select the “Fingerprint” applica-
tion.