QR Code Example
C - Counter
Purpose:
Use this command to define one of maximum 10 automatic counters
used in consecutive numbering applications, such as serial numbers.
Counters can only be used in the Form Edit mode, and not in the
Direct mode.
Syntax:
Cp
1
,p
2
,p
3
,p
4
,[p
5
,],“PROMPT”
.
C- Counter Parameter Descriptions
Parameter
Description
p
1
Counter number (0-9).
p
2
Maximum number of digits for the counter
(0-29).
p
3
Field justification:
L = Left justification.
R = Right justification.
C = Center justification.
N = No justification.
p
4
Step value. Plus or minus sign followed by a
single digit (1-9):
+ Increase.
- Decrease.
Summary of Contents for EasyCoder PC4
Page 1: ...Programmer s Reference Manual ESim for the PC4 and PF8 Printers...
Page 4: ...iv ESim for the PC4 and PF8 Printers Programmer s Reference Manual...
Page 10: ...x ESim for the PC4 and PF8 Printers Programmer s Reference Manual...
Page 14: ...Before You Begin xiv ESim for the PC4 and PF8 Printers Programmer s Reference Manual...
Page 43: ...29 4 ESim Commands This chapter contains a comprehensive list of ESim commands...
Page 144: ...Chapter 4 ESim Commands 130 ESim for the PC4 and PF8 Printers Programmer s Reference Manual...
Page 148: ...Chapter 5 ESim Fonts 134 ESim for the PC4 and PF8 Printers Programmer s Reference Manual...
Page 168: ...Chapter 6 Code Pages 154 ESim for the PC4 and PF8 Printers Programmer s Reference Manual...
Page 178: ...Chapter A Error Handling 164 ESim for the PC4 and PF8 Printers Programmer s Reference Manual...
Page 179: ......