5. Symbologies
Standard 2 of 5
ScanPlus S Series - Installation Manual
97
checked but not transmitted
\43\49\60
barcode length
= <barcode data> + [check digit]
- minimum length possible = 3 characters
- if the codes in your application have fixed lengths, use the "compose 1 or 2 or 3 fixed lengths"
option !!!
compose 1 or 2 or 3 fixed lengths:
\43\4B\60
- enter a number string and scan End Selection
for each length and scan End Selection twice to
finish (Appendix C)
- compose 1 or 2 or 3 fixed lengths provides the
best performance and security if the codes in
your application have fixed lengths
- minimum length possible = 3 characters
any length
\43\4C\00\60
- cancels any fixed length / minimum length
settings and accepts any valid length (3 or more
characters)
Summary of Contents for ScanPlus S Series
Page 1: ...P N 0 360049 02 ScanPlusSSeries Installation Manual ...
Page 8: ...Contents 8 ScanPlus S Series Installation Manual ...
Page 14: ...2 Reset all parameters 14 ScanPlus S Series Installation Manual ...
Page 68: ...4 Data transmission settings OCIA cash registers 68 ScanPlus S Series Installation Manual ...
Page 83: ...5 Symbologies Code 93 ScanPlus S Series Installation Manual 83 minimum length 6 45 42 06 60 ...
Page 120: ...6 Operating settings beeps green indicator LED 120 ScanPlus S Series Installation Manual ...
Page 150: ...C Number codes 150 ScanPlus S Series Installation Manual 8 18 60 9 19 60 end selection 64 60 ...
Page 156: ...Index 156 ScanPlus S Series Installation Manual ...