Chapter 3— Operating the Terminal in a Network
Trakker Antares 242X Handheld Terminal User’s Manual
53
You can configure the following serial port parameters:
• Baud rate
• Data bits
• Parity
• Stop bits
• Flow control
• EOM (End of Message)
• Configuration commands via serial port
• LRC
• SOM (Start of Message)
• Handshake (enabled or disabled)
• Poll (Polling) (enabled or disabled)
• Timeout Delay
Configurable protocol uses EOM to determine one of the following serial
communications modes.
Character Mode
When EOM is disabled, the terminal communicates in Character mode
processing each character. Character mode supports both XON/XOFF
and CTS/RTS flow control.
Frame Mode
When EOM is enabled, the terminal communicates in Frame mode.
When a terminal sends a packet, it adds a protocol character. When a
terminal receives a packet, it strips any protocol characters before it sends
the information to the terminal application. Frame mode supports both
XON/XOFF and CTS/RTS flow control. In Frame mode, you can also
configure the following serial port parameters:
• Configuration commands via serial port
• Handshake
• LRC
• SOM
After you enable Handshake, you can define poll and timeout delay.
Master Polling Protocol
Master Polling Mode D protocol requires the terminal to ask the downline
serial device for data it may have (polling) and to request to send data to
the serial device (selecting). There is no automatic polling, so your
application must poll periodically for data.
Summary of Contents for Trakker Antares 2400
Page 2: ...Trakker Antares 242X Handheld Terminal User s Manual ...
Page 3: ...Trakker Antares 242X Handheld Terminal User s Manual ...
Page 10: ...Contents viii Trakker Antares 242X Handheld Terminal User s Manual ...
Page 113: ...Trakker Antares 242X Handheld Terminal User s Manual 99 Index I ...
Page 121: ......
Page 123: ...Trakker Antares Firmware Version 8 02 Addendum ...
Page 126: ...Contents iv Trakker Antares Firmware Version 8 02 Addendum ...