Chapter 4— Troubleshooting and Maintaining the Terminal
nugget
39
AGaramond
72
Trakker Antares 242X Handheld Terminal User’s Manual
Problems While Configuring the Terminal (continued)
Problem
Possible Solution
You see this error message when exiting the
Configuration Menu:
Commandname
command failed.
Remainder of configuration
not updated.
The two-character name (syntax) of the configuration command that
failed is listed on the first line of the error message. For example, you
may see this message:
SS
command failed.
There may be a problem with the configuration due to a change
made with the Scanner Selection (SS) command.
Check the command listed in the message. To find the command,
use the “Configuration Commands by Syntax” table in Appendix A
of the 2400 Family system manual. Make sure the command is set
correctly for the options and network communications you are using
with the terminal. For help, see Chapter 6, “Configuration
Command Reference,” in the 2400 Family system manual.
On a 2425, you see this error message when
exiting the Configuration Menu:
Network configuration error.
Network is enabled. Terminal
IP address or Controller
(Host) IP address set to an
invalid address of 0.x.x.x or
127.x.x.x. Configuration was
not updated.
The RF network is enabled and there is a problem with the network
configuration. You need to change the terminal IP address, the
controller IP address (host IP address for a TCP/IP network), or
both. Choose Primary Network from the Communications Menu.
The terminal IP address or the controller/host IP address is set to
0.x.x.x or 127.x.x.x. These are invalid addresses. Set a valid IP
address for the terminal and Intermec Gateway, DCS 30X, or host.
For help, see “Using RF Communications on the 2425” on page 55.
If you cannot fix the addressing problem, check with your network
administrator to get the IP address assigned to the terminal and the
Intermec Gateway, DCS 30X, or host.
On a 2425, you see this error message when
exiting the Configuration Menu:
Network configuration error.
Network is enabled. Terminal
IP address and Default Router
address set to the same
address. Configuration was
not updated.
The RF network is enabled and there is a problem with the network
configuration. You need to change the terminal IP address, the
default router address, or both. Choose Primary Network or
Advanced Network from the Communications Menu.
The terminal IP address and the default router address are both set to
the same address. Set a valid IP address for the terminal and the
default router.
For help, see “Using RF Communications on the 2425” on page 55.
If you cannot fix the addressing problem, check with your network
administrator to get the IP addresses for each RF network device.
On a 2425, you see this error message when
exiting the Configuration Menu:
Network configuration error.
Network is enabled. Terminal
IP address or Controller
(Host) IP address set to the
same address. Configuration
was not updated.
The RF network is enabled and there is a problem with the network
configuration. You need to change the terminal IP address, the
controller IP address (host IP address for a TCP/IP network), or
both. Choose Primary Network from the Communications Menu.
The terminal IP address and the controller/host IP address are both
set to the same address. Set a valid IP address for the terminal and
Intermec Gateway, DCS 30X, or host. For help, see “Using RF
Communications on the 2425” on page 55. If you cannot fix the
addressing problem, check with your network administrator to get
the IP address assigned to the terminal and the Intermec Gateway,
DCS 30X, or host.
Summary of Contents for Trakker Antares 2400
Page 2: ...Trakker Antares 242X Handheld Terminal User s Manual ...
Page 3: ...Trakker Antares 242X Handheld Terminal User s Manual ...
Page 10: ...Contents viii Trakker Antares 242X Handheld Terminal User s Manual ...
Page 113: ...Trakker Antares 242X Handheld Terminal User s Manual 99 Index I ...
Page 121: ......
Page 123: ...Trakker Antares Firmware Version 8 02 Addendum ...
Page 126: ...Contents iv Trakker Antares Firmware Version 8 02 Addendum ...