Chapter 4— Troubleshooting and Maintaining the Terminal
Trakker Antares 242X Handheld Terminal User’s Manual
77
Problems With RF Connectivity (continued)
Problem
Possible Solution
You are having problems with your
802.11b RF network coverage.
Make sure that the Medium Density Distribution (MDD) command
on your access point is not enabled. When MDD is enabled, the access
point distributes values for these RF coverage parameters to your
terminal: AP Density, Medium Reservation, and Microwave
Robustness. Changes made by your access point are not reflected in the
terminal menu system.
The Connect icon blinks on the terminal
screen and you see this message:
Unable to connect to
controller. Error 102.
Unable to establish
connection to host. Session
ended.
The 2425 is connected to the access point, but is trying to establish
communications with the Intermec Gateway or DCS 30X and the host
computer. Make sure the terminal is correctly configured for your
network. In a UDP Plus or WTP network, make sure the Intermec
Gateway or DCS 30X is configured and data collection is started. In a
TCP/IP network, make sure the host computer is configured and
running.
If the network is configured correctly, try shutting down and restarting
the Intermec Gateway or DCS 30X to establish communications. You
can also try resetting the terminal. For help, see “Resetting the
Terminal” on page 65.
The Connect icon remains on, but you
cannot establish a terminal emulation
session with the host computer.
*
There may be a problem with the host computer, a problem with the
connection between the Intermec Gateway or DCS 30X and the host
computer, or a problem with the connection between the access point
and the host (TCP/IP). Check with your network administrator to
make sure the host is running and allowing users to login to the system.
Problems While Running Applications
If you are running applications on the terminal and have trouble, check
these possible problems and solutions.
Problems While Running Applications
Problem
Possible Solution
There is not enough memory to load a
program.
You need to free conventional memory by removing files or
applications from drive C. For help, see “Delete File” in Chapter 5 of
the 2400 Family system manual.
The terminal does not boot after you
modified the CONFIG.SYS file to configure
a ROM-DOS RAM drive.
Correct the error in CONFIG.SYS and use the DOS software tools
to recreate drive A with the corrected CONFIG.SYS file.
You see this error message when trying to
load a program:
ERROR LOADING MODULE
LIBRARY NAME:
<
libraryname
>
FILE NAME:
<
filename
>
where
libraryname
and
filename
are the
library and files names of the program.
You need to free conventional memory by removing files or
applications from drive C. For help, see “Delete File” in Chapter 5 of
the 2400 Family system manual.
Summary of Contents for Trakker Antares 2400
Page 2: ...Trakker Antares 242X Handheld Terminal User s Manual ...
Page 3: ...Trakker Antares 242X Handheld Terminal User s Manual ...
Page 10: ...Contents viii Trakker Antares 242X Handheld Terminal User s Manual ...
Page 113: ...Trakker Antares 242X Handheld Terminal User s Manual 99 Index I ...
Page 121: ......
Page 123: ...Trakker Antares Firmware Version 8 02 Addendum ...
Page 126: ...Contents iv Trakker Antares Firmware Version 8 02 Addendum ...