nugget
39
AGaramond
Chapter 4— Troubleshooting and Maintaining the Terminal
Trakker Antares 242X Handheld Terminal User’s Manual
79
Problems Transmitting Data Through the Intermec Gateway or DCS 30X
If you have a problem while running the application on the terminal in a
UDP Plus or WTP network, check these possible communications
problems.
Problems Transmitting Data Through the Intermec Gateway or DCS 30X
Problem
Possible Solution
Transaction Buffer Full.
The buffer holding transactions to be sent to the controller is full. Stop collecting
data with this terminal. Make sure the terminal is communicating with the
Intermec Gateway or DCS 30X and let the terminal send all the transactions in
the buffer before you continue collecting data.
Sending Buffer Transactions.
This is an information message to tell you that buffered transactions are now
being sent to the Intermec Gateway or DCS 30X. You can begin collecting data
again once the message clears.
Transaction Aborted.
The transaction just sent to the Intermec Gateway or DCS 30X was not received.
Try sending the transaction again.
Transmit Error XX, press Enter. There is an error transmitting data to the Intermec Gateway or DCS 30X. XX
represents the status code error. Note the error code in the message and contact
your local Intermec service representative for help. Press
;
to continue.
Receive Error XX, press Enter.
There is an error receiving data from the Intermec Gateway or DCS 30X. XX
represents the status code error. Note the error code in the message and contact
your local Intermec service representative for help. Press
;
to continue.
Shutting down.
The Intermec Gateway or DCS 30X is shutting down. You may continue
collecting data and buffer the transactions in the terminal until the Intermec
Gateway or DCS 30X starts again, or stop collecting data with the terminal.
Controller Shutdown.
The Intermec Gateway or DCS 30X has shut down. You may continue collecting
data and buffer the transactions in the terminal until the Intermec Gateway or
DCS 30X starts again, or stop collecting data with the terminal.
Problems Scanning Bar Code Labels
If you cannot scan bar code labels or you are having trouble with the scan
module, check these possible problems.
Problems Scanning Bar Code Labels
Problem
Possible Solution
A scan module is not installed.
Make sure a scan module is installed correctly. You must have a scan
module, serial module, or input device module attached to use the
terminal.
You have an input device attached to the
input device module and cannot read any bar
code labels.
You may not be using an input device that is supported with the
input device module. Make sure you are using one of the supported
input devices listed in Appendix A, “Specifications.”
Your 242X may not be configured for the input device connected to
it. You must configure the Scanner Selection command and select
the input device that is connected to the terminal. For help, see
“Scanner Selection” in Chapter 6 of the 2400 Family system manual.
Summary of Contents for Trakker Antares 2400
Page 2: ...Trakker Antares 242X Handheld Terminal User s Manual ...
Page 3: ...Trakker Antares 242X Handheld Terminal User s Manual ...
Page 10: ...Contents viii Trakker Antares 242X Handheld Terminal User s Manual ...
Page 113: ...Trakker Antares 242X Handheld Terminal User s Manual 99 Index I ...
Page 121: ......
Page 123: ...Trakker Antares Firmware Version 8 02 Addendum ...
Page 126: ...Contents iv Trakker Antares Firmware Version 8 02 Addendum ...