6-9
6
4800 Baud
9600 Baud
*$+IA5*
*$+IA6*
*$+IA5*
*$+IA6*
19200 Baud
38400 Baud
*$+IA7*
*$+IA8*
*$+IA7*
*$+IA8*
57600 Baud
115200 Baud
*$+IA9*
*$+IAA*
*$+IA9*
*$+IAA*
Example
:
im_command (“$+IA8”,5);
will set the baud rate to 38400.
Beep Volume
Purpose:
Set the beep volume according to operator preference and work environment.
Syntax:
BVdata
Acceptable values for data are:
0
Off
2
Normal
Default:
Normal
Scan:
One of these bar codes:
Beep Volume Off
Beep Volume Normal
*$+BV0*
*$+BV2*
*$+BV0*
*$+BV2*