Configuration Command Reference
6-37
6
Stop Bits
Purpose:
Sets the number of stop bits on the serial port.
Syntax:
ICdata
Acceptable values for data are:
1
1 stop bit
2
2 stop bits
Default:
1 stop bit
Scan:
One of these bar codes:
1 Stop Bit
2 Stop Bits
*$+IC1*
*$+IC2*
*$+IC1*
*$+IC2*
Example
:
im_command (“$+IC2”,5);
will set serial port to 2 stop bits.
Time and Date
Purpose:
Sets the time and date on the computer.
Syntax:
DBdata
Acceptable values for data are 12 digits corresponding to:
yy
00-99
Year
mm
01-12
Month of the year
dd
01-31
Day of the month
hh
01-12
Hour
mm
00-59
Minutes
ss
00-59
Seconds
Default:
920101120000