PRPC Operation: 

Turning the vehicle ignition ON will wake up and initialize the PRPC501 module.  Outputs are 
controlled based on the module’s configuration created using the Intermotive PRPC Programming 
Utility program.  

 

 

When the key is turned OFF,  the PRPC501 module will go into a low power sleep mode .  This may 
take up to TEN minutes, and the LED’s on the module will go out once in sleep mode.  Other vehicle 
activity such as opening doors, inserting key in the ignition, etc. may delay sleep mode.  

 

InterMotive Inc. 
13395 New Airport Rd.  
Auburn, CA 95602 

Phone: (530)-823-1048 

Fax: (530)-823-1516 

Page 12 of 13

 

www.intermotive.net 

 products@intermotive.net 

PRPC501-A-090314-INS  

Inputs: 

To enter Input diagnostic mode, momentarily press the red test button on the module (look 
for “TEST” on the printed circuit board) 

TWO

 times with the ignition on. The on-board yellow 

status LED will blink twice every second in this diagnostic mode. The on-board red fuse LED’s 
will light when a corresponding Input is active:     

Fuse LED 

4A 

4B 

4C 

5A 

5B 

Input # 

J3 Pin # 

10 

10 

12 

12 

Scrolling LED’s: 

This may indicate one of the following errors: 

 

• 

LED’s scrolling sequentially one at a time indicates that an invalid or incomplete VIN was 
captured. 

• 

LED’s scrolling from the middle outward indicates a configuration error.  This can be the result 
of configuring the PRPC for one chassis, but installing it in a different chassis.   

PCB Temperature Load Shedding: 

The PRPC monitors on-board temperature in three different locations. If any one of the readings 
exceeds a predetermined temperature threshold the module will shed one relay load every 2 
minutes to regulate heat. The outputs where the temperature readings are highest will be shut off 
first. If at any time a temperature reading is 5C above the predetermined temperature threshold 
the module will shed one relay load every second until all relays are off. 
 
If this sequence is triggered the module will beep 5 times in about 30 seconds at high pitch before 
shedding any output. 

Summary of Contents for PRPC501-A

Page 1: ...be used This could drive a high temperature dash indicator Another output could be programmed to drive a warning buzzer lamp when the vehicle speed exceeds some limit such as 70mph Electric doors can...

Page 2: ...in stalled in 2 Click the Create Configuration button 3 This screen will come up 4 Configure as desired See the following page for more infor mation Press the Enter button after each entry Note CTO ca...

Page 3: ...using a momentary button as the only input condition and setting the Delays to zero Thus a load could be turned on by pushing a momentary button and turned back off by pushing the button a second time...

Page 4: ...ab and click on Device Manager In the De vice Manager window expand the Ports menu and the download cable will display as USB Serial Port Click the Open File button 1 Open the PRPC ims or configuratio...

Page 5: ...s to mount the module InterMotive Inc 13395 New Airport Rd Auburn CA 95602 Phone 530 823 1048 Fax 530 823 1516 Page 5 of 13 www intermotive net products intermotive net PRPC501 A 090314 INS PRPC Power...

Page 6: ...ctive High Pin 4 White wire Configurable Relay Output 3 Fuse 3 Fuse Selectable Active High Low Pin 5 White wire Configurable Relay Output 2 Fuse 2 Active High Pin 6 White wire Configurable Relay Outpu...

Page 7: ...added together the sum of these fuses must not exceed 20 Amps Note that the placement of fuse 6 will determine whether the output is active high or active low The use of fused outputs 5A or 5B is rec...

Page 8: ...onfigurable Output Active Low Connect the desired outputs to vehicle equipment as needed Tape up unused leads When connecting to relays use relays with appropriate kick back suppression such as Digike...

Page 9: ...lue White stripe Input 7 Active low Pin 8 Pink Black stripe Input 8 Active low Pin 9 Black White stripe Input 9 Active low Pin 10 Orange Black stripe Input 10 Active low Pin 11 Tan Black stripe Input...

Page 10: ...nk harness 6 pin connector is NOT connected to the PRPC501 module 2 Turn the vehicle key on engine off 3 Insert the Data Link harness 6 pin connector into the PRPC501 module 4 The PRPC s red fuse LEDs...

Page 11: ...tput the associated on board red LED will illuminate No fuse sensing is done on outputs that are not configured to turn on Low Current Outputs To enter LCO diagnostic mode momentarily press the red te...

Page 12: ...e on board red fuse LED s will light when a corresponding Input is active Fuse LED 1 2 3 4A 4B 4C 5A 5B Input 1 2 3 4 5 6 7 8 J3 Pin 1 2 3 4 5 6 7 8 6 9 9 7 10 10 8 12 12 Scrolling LED s This may indi...

Page 13: ...the PRPC fails any step in the Post Installation Test review the installation instructions and the loaded configuration by running the Graphical User Interface application If necessary call InterMotiv...

Reviews: