InterMotive Inc.
13395 New Airport Rd.
Auburn, CA 95602
Phone: (530)-823-1048
Fax: (530)-823-1516
Page 3 of 13
www.intermotive.net
products@intermotive.net
PRPC501-A-090314-INS
Setting Pin Mode— PRPC Application Software
Momentary
: Output follows condition set but with a turn on delay, and a turn off delay. Setting ‘On
Delay’ and ‘Off Delay’ to zero causes the output pin to simply “follow” the condition set being true (ON)
and false (OFF).
Latching
: This mode will latch an output pin ON, starting ‘On Delay’ seconds after the conditions are
met, and will keep it ON even after the conditions are no longer true. It will then latch the output OFF,
following ‘Off Delay’ seconds after the conditions are met again. It can be thought of as toggle
On/toggle Off. The simplest use would be when using a momentary button as the only input condition
and setting the Delays to zero. Thus a load could be turned on by pushing a momentary button, and
turned back off by pushing the button a second time.
Time Hold
: The output pin goes ON after the conditions become true, and stays ON for the selected
‘On Time’, regardless of the conditions. Off Time is Not Applicable.
Time Delay
: Output is turned ON after the selected ‘delay’ time after the conditions are met. It
stays on for selected ‘On time’, regardless of input conditions.
Flashing—Momentary
: Used for creating a flashing output. When conditions are met, output flash-
es. When conditions are no longer met, flashing stops. Flashing ON and OFF times (duty cycle) are
controlled by entering the following values.
Flashing - Latching
: Same as above, except flashing will continue after conditions are no longer
true, and will stop when conditions become true again—toggle ON, toggle OFF. Duty cycle is con-
trolled by the ON and OFF times.